REMOVAL OF SQUEEGEE MOUNT ASSEMBLY
1
Remove the squeegee tool assembly from the machine then start the engine and lower the squeegee mount.
2
See Figure 3. Remove the (4) Parallel Arms (J) (two per side) from the squeegee mount Towers (K) as shown. This will allow movement
of the Mount Assembly (L) and allow easy access to the lift cylinder rod Nut (M).
3
Remove the lift cylinder rod nut. Next start the engine and raise the lift cylinder to separate it from the mount. This allows the needed clearance
to remove the mount assembly from underneath the machine.
Reinstallation Steps
1
Position the mount assembly under machine and block up the center of the mount (3" approx.) then reattach arms. Note: Reference Figure
3 for the correct orientation of the L & R side arm assemblies.
2
Add additional blocking under the mount to raise it to where the cylinder rod end is installed through its mounting hole. Then install the washer
and nut to retain the lift cylinder to the mount. Note: Tighten cylinder nut so there is no play between the cylinder and mount, but do not over-
tighten.
3
Remount the squeegee tool and test squeegee for proper water pick-up. See in this manual Squeegee Maintenance for tool adjustment
instructions.
SQUEEGEE LIFT CYLINDER REMOVAL
1
Remove the squeegee tool assembly from the machine then start the engine and lower the squeegee mount. This will allow easy access to
the lift cylinder rod Nut (M) (see Figure 3).
2
Then remove the lift cylinder rod Nut (M). Next start the engine and raise (shorten) the cylinder to separate it from its mount.
3
Remove the two hydraulic hoses and plug and cap.
4
Remove the rear solution tank panel assembly (lighted lens) secured by (3) screws. This allows access to the cylinders top mount bracket.
Remove the hex screw and pull the cylinder out from underneath the machine.
5
To reinstall follow the above directions in reverse order and test for proper operation and check for leaks.