36 - FORM NO. 56043094 / Captor
™
4300, 4800, 5400 / CR 1100, 1200, 1400
HOPPER SYSTEM
FRONT
K
L
J
I
H
FIGURE 2
DUMP DOOR CYLINDER REMOVAL
To access:
1
Raise Hopper Cover and engage hopper cover prop rod.
2
See Figure 2. Raise and support Shaker Assembly (H).
3
Remove filter assembly.
4
Remove (11) Bolts (I) and remove Access Panel (J).
To remove cylinder:
1
Remove the two hoses from Door Cylinder (K). Note: Mark hose locations to insure correct connections when reassembling.
CAUTION!
There may be oil in hoses and cylinder, be prepared to plug hoses and cap cylinder connections.
2
Remove lower and upper cotter pins and Cylinder Pins (L).
3
Remove cylinder.
To reassemble:
1
Mount cylinder end to upper mounting bracket using pin and cotter pin.
2
Pull cylinder rod out until clevis meets with dump door arm.
3
Mount cylinder rod end to dump door arm using pin and cotter pin.
4
Reconnect the two hoses in correct position.
5
Check for proper operation and leaks.
6
Reinstall access cover and filter assembly.
7