FORM NO. 56043094 / Captor
™
4300, 4800, 5400 / CR 1100, 1200, 1400 - 29
SWEEPING SYSTEM
SIDE BROOM MOTOR REMOVAL
1
Lower the side broom(s). Note: The main broom must be first lowered to allow the side brooms to be lowered.
2
Raise hopper to a comfortable work position (eye level). Then remove the side broom and plastic broom guard.
3
Mark and remove the hydraulic hoses to the motor that needs to be serviced (plug and cap).
4
See Figure 4. Pull out motor bracket to (extend) gain access to motor mounting hardware. Then remove the (2) (U) Screws and (V) Nuts
that fastens the motor to its mount. Complete the removal of the motor by lifting it through the hole on the motor bracket.
5
Salvage the motor Drive Hub (W). Use a pin punch to drive out the Roll Pin (X) and pull the hub from the motor shaft. Install a serviced or
new motor by following the above steps in reverse order.
FIGURE 4
U
V
X
W
T
FRONT