background image

Power Blower

Operator’s Manual

MODEL

PB-211

WARNING   

   DANGER

Read rules for safe operation and all instructions carefully.  ECHO provides this Operator’s
Manual which must be read and understood for proper and safe operation.

X750-002 12 2
X750111-070 2

Printed in Japan 0503Bm 0044 ES

Summary of Contents for PB-211

Page 1: ...al MODEL PB 211 WARNING DANGER Readrulesforsafeoperationandallinstructionscarefully ECHOprovidesthisOperator s Manualwhichmustbereadandunderstoodforproperandsafeoperation X750 002 12 2 X750111 070 2 Printed in Japan 0503Bm 0044 ES ...

Page 2: ...ions 7 Description 8 EmissionControl 8 Contents 8 Specifications 10 Assembly 11 BlowerApplication 11 Pre Operation 11 Fuel 11 Operation 13 StartingColdEngine 13 StartingWarmEngine 14 Stopping Engine 14 OperatingBlower 15 Specifications descriptions and illustrative material in this literature are as accurate as known at the time of publica tion but are subject to change without notice Illustration...

Page 3: ...maintenance of the unit Locate these safety decals on your unit The complete unit illustration found in the DESCRIPTION section will help you locate them Make sure the decals are legible and that you understand and follow the instructions on them If a decal cannot be read a new one can be orderedfromyourECHOdealer DECALS SAFETY Read and follow all safety precautions in the operator s manual Operat...

Page 4: ...ACCESSORIES INTERNATIONAL SYMBOLS EQUIPMENT Before operation a complete check of the unit must be performed Check unit for loose missing nuts bolts and screws Tighten and or replace as needed Inspect fuel lines tank and area around carburetor for fuel leaks DO NOT operate unit if leaks are found Spark Arrestor Muffler The spark arrestor muffler controls the exhaust noise and prevents hot glowing p...

Page 5: ...ection Wear eye protection that meets ANSI Z87 1 or CE requirements whenever you operate the blower Hand Protection Wear no slip heavy duty work gloves to improve your grip on the blower handle Gloves also reduce the transmission of machine vibration to your hands Breathing Protection Wear a face mask to protect against dust Hearing Protection ECHO recommends wearing hearing protection whenever un...

Page 6: ...required Protective Equipment and clothing Keep long hair away from engine and blower intake Retain hair with cap or net Start unit on ground with throttle at idle Check that blower pipe is not blocked by the ground or by any objects KeepASolidStance Maintain footing and balance at all times Do not stand on slippery uneven or unstable surfaces Do not work in odd positions or on ladders Do not perf...

Page 7: ... Repetitive Stress Injuries It is believed that overusing the muscles and tendons of the fingers hands arms and shoulders may cause soreness swelling numbness weakness and extreme pain in those areas Certain repetitive hand activities may put you at a high risk for developing a Repetitive Stress Injury RSI AnextremeRSIconditionisCarpalTunnelSyndrome CTS which could occur when your wrist swells and...

Page 8: ...lend TM 2 stroke oil sample PRODUCTEMISSIONDURABILITY The 300 hour emission durability period is the time span selected by the manufacturer certifying the engine emis sions output meets applicable emissions regulations provided that approved maintenance procedures are followed as listed in the Maintenance Section of this manual DESCRIPTION EMISSION CONTROL California Tier 2 The emission control sy...

Page 9: ...stor prevents hot glowing particles of carbon from leaving the muffler 5 RECOILSTARTERHANDLE Pullrecoilhandleslowlyuntilrecoilstarterengages thenquicklyandfirmly When engine starts return handle slowly DO NOT let handle snap back or damage to unit will occur 6 FUELTANKCAP Forclosingthefueltank 7 AIRCLEANER Containsreplaceableairfilterelement 8 CHOKE Pull choke knob to COLD START to close choke for...

Page 10: ...ir cooled two stroke single cylinder gasoline engine 21 2 mL 1 39 cu in 30 0 mm 1 18 in 30 0 mm 1 18 in WalbroDiaphragmw purge Flywheel Magneto capacitor discharge ignition type NGK BPM 8Y Gap 0 65 mm 0 026 in Spark Arrestor Muffler w Catalyst Mixed Gasoline and Two stroke Oil 50 1 ECHO High Performance two stroke air cooled engine oil 89 Octane unleaded DO NOT use fuel containing methyl alcohol G...

Page 11: ...ontain up to 15 MTBE methyl tertiary butyl ether Gasohol containing methyl wood alcohol is NOT approved TwoStrokeOil Atwo strokeengineoilmeetingISO L EGD ISO CD 13738 and J A S O FC Standards must be used Echo brand premium Power Blend TM Universal 2 Stroke Oil meets these standards Engine problems due to inadequate lubrication caused by failure to use an ISO L EGDandJ A S O FCcertifiedoil suchasE...

Page 12: ...oline 3 Close container and shake to mix oil with gasoline 4 Add remaining gasoline close fuel container and remix IMPORTANT Spilled fuel is a leading cause of hydrocarbon emissions Some states may require the use of automatic fuel shut off containers to reduce fuel spillage After use DO NOT store a unit with fuel in its tank Leaks can occur Return unused fuel to an approved fuel storage container...

Page 13: ...roduct indoors or in inadequately ventilated areas STARTING COLD ENGINE WARNING DANGER When engine is started confirm if there is not any abnormal vibration or sound If there is abnormal vibration or sound ask your dealer to repair 1 Stop Switch Start Run Turn switch to RUN position 2 Close Choke Cold Start Pull choke all the way out Close position IMPORTANT Recoil starter Use short pulls only 1 2...

Page 14: ... Turn switch to RUN position 2 Place the blower on a flat clear area Firmly grasp throttle grip with left hand and rapidly pull recoil starter handle rope until engine fires IMPORTANT Recoil starter Use short pulls only 1 2 2 3 of rope for starting Do not allow the rope to snap back in Always hold the unit firmly NOTE If engine does not start after 4 pulls use Cold Start Procedure STOPPING ENGINE ...

Page 15: ... during appropriate hours 2 Allow the engine to warm up at a fast idle for a few minutes 3 Use lower speed to blow dry leaves from a lawn or flower bed Additional speed may be necessary to clean grass and leaves from walks patios and drives or to move gravel dirt snow bottles or cans from a driveway street parking lot or stadium NOTE Never use a higher speed setting than necessary to perform a tas...

Page 16: ...he various part numbers required for that task Ask your ECHO dealer for these parts MAINTENANCE INTERVALS COMPONENT SYSTEM MAINTENANCE PROCEDURE REQ D SKILL LEVEL DAILY OR BEFORE USE EVERY REFUEL 3 MONTHS OR 90 HOURS 6 MONTHS OR 270 HOURS YEARLY Cylinder Exhaust Port Inspect Clean Decarbon 3 I C Fuel System Leaks Replace 3 R Air Filter Inspect Clean Replace 1 I C R Choke Inspect Clean 2 I C Fuel F...

Page 17: ... original side out FUEL FILTER Level1 WARNING DANGER FuelisVERYflammable Useextremecarewhenmixing storingor handling 1 Use a clean rag to remove loose dirt from around fuel cap and empty fuel tank 2 Use the fuel line hook to pull the fuel line and filter from the tank 3 Remove the filter from the line and install the new filter Fuel filter Air cleaner cover CHECK FUEL SYSTEM Level 1 or 3 1 Check b...

Page 18: ...15 17 N m 130 145 in lb COOLING SYSTEM Level2 IMPORTANT To maintain proper engine operating temperatures cooling air must pass freely through the cylinder fin area This flow of air carries combustion heat away from the engine Overheating and engine seizure can occur when Air intakes are blocked preventing cooling air from reaching the cylinder Dust and grass build up on the outside of the cylinder...

Page 19: ...e screen if plugged with carbon deposits NOTE When cleaning carbon deposit be careful not to damage the catalyticelementinsidemuffler 2 Install spark arrestor screen gasket and cover 3 Tighten all screws securely Cylinder Exhaust Port Level3 IMPORTANT The cylinder exhaust port must be inspected and cleaned of excess carbon every 3 months or 90 hours of operation in order to maintain this engine wi...

Page 20: ...run several minutes to bring to operating temperature Flash choke twice during warm up to clear any air from the fuel system 3 Stop engine Turn H speed needle CCW Counterclock wise to stop Turn L speed needle midway between full CW Clockwise stop and CCW stop 4 Idle Speed Adjustment Before adjusting blower install all blower pipes Start engine turn idle speed adjustment screw either CW or CCW unti...

Page 21: ...65 mm 0 026 in Covered with carbon Clean or replace Fouled with fuel Clean or replace Plug defective Replace plug Air filter Air filter dirty Normal wear Clean or replace Fuel filter Fuel filter dirty Contaminants residues in fuel Replace Fuel vent Fuel vent plugged Contaminants residues in fuel Clean or replace Spark plug Plug dirty worn Normal wear Clean and adjust or replace Carburetor Improper...

Page 22: ...o remove fuel from the carburetor 7 Remove the spark plug and pour 7 mL 1 4 oz of fresh clean ECHO 2 stroke engine oil into the cylinder through the spark plug hole A Place a clean cloth over the spark plug hole B Pull the recoil starter handle 2 or 3 times to distribute the oil inside the engine C Observe the piston location through the spark plug hole Pull the recoil starter handle slowly until ...

Page 23: ...23 POWER BLOWER OPERATOR S MANUAL NOTES ...

Page 24: ...f this product you may call the ECHO ConsumerProductSupportDepartmentat1 800 673 1558from8 30am to 4 30 pm Central Standard Time Monday through Friday Before calling please know the model and serial number of your unit to help your Consumer Product Support Representative WARRANTY REGISTRATION You may register your Echo equipment using the warranty registration card or register on line at www echo ...