Squeegee installation
Install the squeegee (25) and fasten it with the handwheels (26), then connect the vacuum hose (15) to the squeegee.
Adjust the squeegee with the handwheel (27) so that the rear blade - in all its length - touches the floor.
Guide to match squeegees and brush/pad-holder decks
Model
Deck
Squeegee model
BA 601
(*)
Deck with two brushes (18), brush diameter 305 mm
Aluminium width 838 mm
BA 651
Deck with two brushes (18), brush diameter 330 mm
Aluminium width 889 mm
BA 751
Deck with two brushes (18), brush diameter 355 mm
Aluminium width 889 mm
BA 851
Deck with two brushes (18), brush diameter 430 mm
Aluminium width 1,067 mm
BA 751 C
Deck with two cylindrical brushes (19), brush length 690 mm
Aluminium width 889 mm
(*) Optional model
Solution tank filling
NOTE
If the machine is equipped with EDS™ - ECO Dosage Solution [switch (77) (optional)] pour clean water in the tank,
otherwise pour solution.
Remove the plug (47) to reach the filler (8).
(For machines without EDS™ - ECO Dosage Solution)
Fill the tank (20) with a solution suitable for the work to be performed.
Do not fill the solution tank completely, leave few inches from the edge. Use the hose (17) as reference.
Always follow the dilution instructions on the label of the chemical product used to prepare the solution.
The solution temperature must not exceed 40°C.
WARNING!
Use only low-foam and non-flammable detergents, intended for automatic scrubber applications.
(For machines with EDS™ - ECO Dosage Solution)
Fill the tank (20) with clean water by using the filler neck (8).
Do not fill the clean water tank completely, leave a few centimetres from the edge. Use the hose (17) as reference.
The water temperature must not exceed 40°C.
Detergent tank filling (for machines with EDS™ - ECO Dosage Solution)
Open the cover (22) and check that the recovery tank (21) is empty, otherwise empty it with the drain hose (16).
Grasp the handle (41) and carefully lift the tank (40).
Open the plug (46).
Fill the tank (45) with a detergent suitable for the work to be performed (highly concentrated detergent).
Do not fill the detergent tank completely, leave a few inches from the edge.
CAUTION!
Use only low-foam and non-flammable detergents, intended for automatic scrubber applications.
NOTE
In case of new system, system emptied for cleaning, etc., wait for the hoses to fill up completely before turning on the
EDS™ - ECO Dosage Solution. In order to fill the system quickly it may be useful to drain the EDS™ - ECO Dosage
Solution once or several times (see the procedure in Maintenance chapter).
1.
2.
1.
2.
1.
2.
3.
4.
Summary of Contents for BA 651
Page 8: ...DEUTSCH BETRIEBSANLEITUNG 9097293000 1 2008 03 A BA 651 BA 751 BA 851 BA 751 C P100172 ...
Page 38: ...FRANÇAIS MANUEL OPERATEUR 9097293000 1 2008 03 A BA 651 BA 751 BA 851 BA 751 C P100172 ...
Page 68: ...ENGLISH USER MANUAL 9097293000 1 2008 03 A BA 651 BA 751 BA 851 BA 751 C P100172 ...
Page 98: ...NEDERLANDS GEBRUIKSAANWIJZING 9097293000 1 2008 03 A BA 651 BA 751 BA 851 BA 751 C P100172 ...
Page 123: ......
Page 124: ......