Foot Pedal Neutral Position and Dead-band Adjustment:
FACTORY DEFAULT: 2
RANGE: 1 - 3
The various scrub and sweep functions on the Falcon are activated when the foot pedal is moved from the neutral position. The engine neutral-start
relay is also activated when the foot pedal is moved from the neutral position. These functions are triggered via a position sensor mounted on the
hydrostat. Whenever adjustments are made to the hydrostat unit, the neutral position will need to be programmed. Also, the neutral dead-band
(sensitivity) can be adjusted if necessary. To set the neutral position and adjust the neutral dead-band perform the following steps:
1)
Turn the
main power key switch
to the
off
position.
2) Depress the foot pedal to the full reverse position.
3) Allow the foot pedal to slowly return to the neutral position and do not move the pedal during the remainder of this procedure.
4)
Press and hold the
engine speed switch
.
5)
While holding the engine speed switch turn the
main power key switch
to the
on
position.
6) Continue to hold the engine speed switch until all indicators turn off (approximately two seconds).
7)
Release the engine speed switch.
8) The service indicator will now be lit. Pressing and releasing the
engine speed switch
will increase the deadband to the middle range.
Pressing and releasing the
engine speed switch
again will increase the deadband to the maximum range. The next press will return the
deadband to the minimum range. The service indicator will be on steady if the minimum range is selected, it will flash at a slow rate if the
middle range is selected, and it will flash at a fast rate if the maximum range is selected.
9) To save the new setting, turn the
main power key switch
to the
off
position.
10) The new setting will be saved and will remain in effect until it is changed again.
Recall Of Stored Fault Codes:
Whenever an electrical system fault is detected by the main control unit, one or more fault codes are displayed and stored by the control unit. If it
is desired, the fault code (if any) from the previous operation of the machine can be recalled for troubleshooting purposes. To recall the last stored
fault codes perform the following steps:
1)
Turn the
main power key switch
to the
off
position.
2)
Press and hold the
horn switch
.
3)
While holding the horn switch, turn the
main power key switch
to the
on
position.
4) Continue to hold the horn switch until all indicators turn off (approximately two seconds).
5)
Release the horn switch.
6) If there were previously no error codes stored, the service indicator will be lit continuously. If error codes were stored, the service indicator will
now flash the stored code(s).
7)
To clear the stored codes press and release the
horn
switch
. The service indicator will light continuously.
8) To exit the error code recall mode, turn the
main power key switch
to the
off
position.