FORM NO. 56043129 - SR 1900 -
59
HYDRAULIC SYSTEM
Hydraulic Truth Table
Electrical Solenoid’s energized Status
Solenoid Functions
S1
S2
S3
S4
S5
S6
S7
S8
S9
Hopper Raise (UP)
X
X
Hopper Lower (DN)
X
Dump Door Open
X
Dump Door Closed
X
Main Broom State ON
X
X
Main /Side Broom State ON
X
X
X
Dust Control ON Wand State
(**)
X
X
Dust Control OFF Bypass (*)
X
Side Broom Lower
X
Side Broom Raise & turn
OFF side broom motor
0V
No Hydraulic Manifold
Functions
System
overloaded
in relief
S6 not
energized
(***)
Notes:
* Operator sweeping wet debris with the dust control fan (impeller) turned off.
** Operator using vacuum wand option. The dust control fan operates with the machines drive stationary. To vacuum attach the suction hose wand
to the special hopper inlet fitting.
*** The S6 solenoid valve assembly bypasses the sweep system components and sends its hydraulic oil flow to tank when S6 is de-energized (0
volts).
HYDRAULIC MANIFOLD ASSEMBLY COMPONENT LOCATION KEY
Note: the combined electrical solenoid and hydraulic valve cartridge assembly can be serviced separately.
Item #
Component Description & Hydraulic Circuit Function
S1
Solenoid coil & valve cartridge, hopper dump door (open), coil 8 Ohms
S2
Solenoid coil & valve cartridge, main broom System, coil 8 Ohms
S3
Solenoid coil & valve cartridge, side broom system, coil 8 Ohms
S4
Solenoid coil & valve cartridge, dust control (wand state), coil 8 Ohms
S5
Solenoid coil & valve cartridge, hopper lift system (raise), coil 8 Ohms
S6
Solenoid coil & valve cartridge, hydraulic circuit on/off (by-pass), 8 Ohms
S7
Solenoid coil & valve cartridge, hopper Dump door (close), coil 8 Ohms
S8
Solenoid coil & valve cartridge, dust control fan off (by-pass), coil 6 Ohms
S9
Solenoid coil & valve cartridge, hopper lift (close), coil 8 Ohms
Notes: (A) The solenoid coils w/connector S1 – S7 & S9 are identical and can be swapped for (T.S.) troubleshooting. (B) The solenoid coil w/
connector S8 is different only one is used. (C)The valve cartridges for S1, S2 & S4 are identical, S3 & S7 the same and S5 & S9 the same and can
be swapped for T.S. (D)The S6 & S8 valve cartridges are different configurations one of each are only used.
Item #
Additional Hydraulic Manifold Components Descriptions
X1
Cartridge, side broom lift cylinder piloted 3/2 directional valve
X2
Cartridge, side broom piloted check valve
X3
Orifice (.038 Dia.), hopper raise control
X4
Orifice (.086 Dia.), hopper dump door control
X5
Orifice (.078 Dia.), hopper lower control
X6
Cartridge, broom system flow divider
X7
Cartridge, steering system flow divider
X8
Check valve, side broom(s)
X9
Cartridge, hopper lift free check
X10
Pressure relief valve (2500 PSI.), manifold block