Wheel System, Traction
195
Service Manual – SC6500
™
Troubleshooting Chart
Flash
Code
#
Programmer LCD
Display
/ Effect Of Fault
Possible Cause(s)
Set
/
Clear
Conditions
39
Main Contactor Did Not
Close
ShutdownMotor;
ShutdownMainContactor;
ShutdownEMBrake;
ShutdownThrottle;
FullBrake; ShutdownPump.
1. Main contactor did not close.
2. Main contactor tips are
oxidized, burned, or not
making good contact.
3. External load on capacitor
bank (B+ connection terminal)
that prevents capacitor bank
from charging.
4. Blown B+ fuse.
Set
: With the main contactor
commanded closed, the
capacitor bank voltage (B+
connection terminal) did not
charge to B+.
Clear
: Cycle KSI.
41
Throttle Wiper High
ShutdownThrottle.
1. See Monitor menu » Inputs:
Throttle Pot.
2. Throttle Pot. wiper voltage too
high.
Set
: Throttle pot wiper (pin 16)
voltage is higher than the high
fault threshold (can be changed
with the VCL function Setup_
Pot_Faults).
Clear
: Bring throttle pot
wiper voltage below the fault
threshold.
42
Throttle Wiper Low
ShutdownThrottle.
1. See Monitor menu » Inputs:
Throttle Pot.
2. Throttle pot wiper voltage too
low.
Set
: Throttle pot wiper (pin 16)
voltage is lower than the low
fault threshold (can be changed
with the VCL function
Set
up_
Pot_Faults).
Clear
: Bring throttle pot
wiper voltage above the fault
threshold.
43
Pot2 Wiper High
FullBrake.
1. See Monitor menu » Inputs:
Pot2 Raw.
2. Pot2 wiper voltage too high.
Set
: Pot2 wiper (pin 17) voltage
is higher than the high fault
threshold (can be changed with
the VCL function
Set
up_Pot_
Faults()).
Clear
: Bring Pot2 wiper voltage
below the fault threshold.
44
Pot2 Wiper Low
FullBrake.
1. 1. See Monitor menu » Inputs:
Pot2 Raw.
2. 2. Pot2 wiper voltage too low.
Set
: Pot2 wiper (pin 17) voltage
is lower than the low fault
threshold (can be changed with
the VCL function
Set
up_Pot_
Faults()).
Clear
: Bring Pot2 wiper voltage
above the fault threshold.