Scrub System, Cylindrical
112
Service Manual – SC6500
™
10. After each adjustment, hold the
Spring Housing Assembly
, run the actuator in and out and check both
dimensions.
11. Reinstall the
Cam Adjuster Cover
.
12. After adjusting the actuator
Spring Housing Assembly
dimensions, refer to the
Removal
and Installation/Scrub Deck Lift
Actuator
section to reassemble
it in the machine. Refer to the
adjacent drawing to correctly
mount the top of actuator motor to
the chassis by model size.
Service Note:
Note the correct orientation of the
Spring Housing Assembly
when installing the
complete motor assembly and also run the
Spring Housing Assembly
to the
Retracted
(in) position before you install it in the machine.