We
reserve the right to make changes
Page 45 of 49
Max voltage VFD 5
3 Maximum voltage for analog VFD de-
vice output
Preheater settings
2 Preheater settings
Preheater device type
None / EHD / BAH /
ePHeat
4 Set the type of installed preheater
device
Polar functionality
3 Set polar functionality to system
Polar functionality
2 Enable/Disable the Polar functionality
No-Frost setpoint.
2 Base regulation point for Deice Heater
working.
Preheater setpoint (°C)
3 Outdoor temperature to allow pre-
heater
Heater off time (min)
min
3 Minimum preheater power off time
Hose damper
3 Hose damper settings
EHD hold time
(h)
2
timer 3 Time between hose temperature sam-
pling
Hose stabilising
(min)
10
min
3 Time for hose temperature stabilisa-
tion
BAH settings
3 BAH settings
BAH hold time
(h)
2
timer 3 Time between time for BAH tempera-
ture sampling
BAH stabilisa-
tion (min)
10
min
3 Time for BAH temperature stabilisation
Legionella mode
1 Interval for anti- legionella function
Legion mode
Off / Weekly / Daily
2 Legion mode
Start legionella now
Off / On
1 Force system to run anti-legionella
function now
Day for anti-legionella
5
2 Select which day to run anti-
legionella.
Legionella start (h)
15
2 Time of day to run anti- legionella
function
DHW settings
2 Settings for hot water production
DHW minumum temp.
(°C)
36.0
°C
2 Minimum hot water temperature