5.3. Speech connection
Display module
Display
Establish speech connection
If you answer the call (receiver off the hook, pressing speech key),
a speech connection is established.
Terminate speech connection
The speech connection is interrupted:
• as soon as the receiver of the internal unit is on the hook or
the speech key is pressed
• as soon as the set speaking time has elapsed
The standby mode will reappear on the screen.
5.4. Open door by entering code
Code lock module and display module
Display
Enter the correct code
The code is correct
Press smart key
or * on the code lock module. A screen
to enter the code appears on the display (image 23).
The following screen will appear:
Enter a 1- to 4-digit code in the code lock module.
Confirm using smart key
or # on the code lock module.
The code is not correct
If the code is invalid, the door opener is not activated.
Press the smart key
to enter the code again.
If you enter the wrong access code three times in a row, the code
lock will be blocked for 180s.
6. TROUBLESHOOTING
6.1. In case of any issues, always first check whether the following voltages are present using a multimeter:
Between terminals …
the following voltage must be present
a and b
24 +/- 1V In circuit voltage 19-23V (depending on state and distance)
b and P
7 +/- 1V In circuit voltage 20 – 27V (depending on state and distance)
M and P
7 +/- 1V In circuit voltage 20 – 27V (depending on state and distance)
M and V1 or V2
3 … 6 Vdc