![Niko 05-336 Manual Download Page 3](http://html1.mh-extra.com/html/niko/05-336/05-336_manual_1689602003.webp)
05-336
EN
PM005-33600R22463
3
4
Select the base time
P
M
CH1 CH2
> 1,6 s
LED 2TB + 1TB flash alternately.
LED CH1 or LED CH2 lights up.
The display shows the base time used with
multiplier A, C, E, F or H. Mind that the display
can only show one digit. Depending on how
many times a certain digit is displayed, the
base time will increase as per the selected
multiplier. For example, if the digit 1 is shown
for the first time, the base time will equal
1 second. If the same digit appears for the
second time, the base time will amount to 11
seconds. The third time said digit is shown, the
base time will be 21 seconds, etc.
5
Save the base time
P
M
CH1 CH2
1x briefly
LED CH1 or LED CH2 and LED 2TB + 1TB
light up.
Display: multipier (A) flashes
Currently selected multiplier is shown
6
Select the multiplier to be
used for the set base time
(see § 4.2.5)
P
M
CH1 CH2
repeatedly
LED of the selected output and LED 2TB +
1TB light up
7
Save switching time (=base
time multiplied by the
multiplier)
P
M
CH1 CH2
1x briefly
LED CH1/CH2 and LED 2TB + 1TB light up.
Display: multipier (A) flashes
If all red LEDs go out, the receiver is ready for
operation
4.2.4. CONVERSION TABLE OF TIMER
Conversion seconds with multiplier in time (Hr: min: sec)
Multiplier for base time
Seconds
Display
1 (
A
)
10 (
C
)
100 (
E
)
1000 (
F
)
1
1
0:00:01
0:00:10
0:01:40
0:16:40
2
2
0:00:02
0:00:20
0:03:20
0:33:20
3
3
0:00:03
0:00:30
0:05:00
0:50:00
4
4
0:00:04
0:00:40
0:06:40
1:06:40
5
5
0:00:05
0:00:50
0:08:20
1:23:20
6
6
0:00:06
0:01:00
0:10:00
1:40:00
7
7
0:00:07
0:01:10
0:11:40
1:56:40
8
8
0:00:08
0:01:20
0:13:20
2:13:20
9
9
0:00:09
0:01:30
0:15:00
2:30:00
10
0
0:00:10
0:01:40
0:16:40
2:46:40
11
1
0:00:11
0:01:50
0:18:20
3:03:20
12
2
0:00:12
0:02:00
0:20:00
3:20:00
13
3
0:00:13
0:02:10
0:21:40
3:36:40
14
4
0:00:14
0:02:20
0:23:20
3:53:20
15
5
0:00:15
0:02:30
0:25:00
4:10:00
16
6
0:00:16
0:02:40
0:26:40
4:26:40
17
7
0:00:17
0:02:50
0:28:20
4:43:20
18
8
0:00:18
0:03:00
0:30:00
5:00:00
19
9
0:00:19
0:03:10
0:31:40
5:16:40
20
0
0:00:20
0:03:20
0:33:20
5:33:20
21
1
0:00:21
0:03:30
0:35:00
5:50:00
22
2
0:00:22
0:03:40
0:36:40
6:06:40
23
3
0:00:23
0:03:50
0:38:20
6:23:20
24
4
0:00:24
0:04:00
0:40:00
6:40:00
25
5
0:00:25
0:04:10
0:41:40
6:56:40
26
6
0:00:26
0:04:20
0:43:20
7:13:20
27
7
0:00:27
0:04:30
0:45:00
7:30:00
28
8
0:00:28
0:04:40
0:46:40
7:46:40
29
9
0:00:29
0:04:50
0:48:20
8:03:20
30
0
0:00:30
0:05:00
0:50:00
8:20:00
31
1
0:00:31
0:05:10
0:51:40
8:36:40
32
2
0:00:32
0:05:20
0:53:20
8:53:20
33
3
0:00:33
0:05:30
0:55:00
9:10:00
34
4
0:00:34
0:05:40
0:56:40
9:26:40
35
5
0:00:35
0:05:50
0:58:20
9:43:20
36
6
0:00:36
0:06:00
1:00:00
10:00:00
37
7
0:00:37
0:06:10
1:01:40
10:16:40
38
8
0:00:38
0:06:20
1:03:20
10:33:20
39
9
0:00:39
0:06:30
1:05:00
10:50:00
40
0
0:00:40
0:06:40
1:06:40
11:06:40
41
1
0:00:41
0:06:50
1:08:20
11:23:20
42
2
0:00:42
0:07:00
1:10:00
11:40:00
43
3
0:00:43
0:07:10
1:11:40
11:56:40
44
4
0:00:44
0:07:20
1:13:20
12:13:20
45
5
0:00:45
0:07:30
1:15:00
12:30:00
46
6
0:00:46
0:07:40
1:16:40
12:46:40
47
7
0:00:47
0:07:50
1:18:20
13:03:20
48
8
0:00:48
0:08:00
1:20:00
13:20:00
49
9
0:00:49
0:08:10
1:21:40
13:36:40
50
0
0:00:50
0:08:20
1:23:20
13:53:20
51
1
0:00:51
0:08:30
1:25:00
14:10:00
52
2
0:00:52
0:08:40
1:26:40
14:26:40
53
3
0:00:53
0:08:50
1:28:20
14:43:20
54
4
0:00:54
0:09:00
1:30:00
15:00:00
55
5
0:00:55
0:09:10
1:31:40
15:16:40
56
6
0:00:56
0:09:20
1:33:20
15:33:20
57
7
0:00:57
0:09:30
1:35:00
15:50:00
58
8
0:00:58
0:09:40
1:36:40
16:06:40
59
9
0:00:59
0:09:50
1:38:20
16:23:20
60
0
0:01:00
0:10:00
1:40:00
16:40:00
4.2.5. MULTIPLIER OVERVIEW
Multiplier to be used for the set base time.
Multipier
A
1 x seconds
C
10 x seconds
E
100 x seconds
F
1000 x seconds
H