23
Nihon Bisoh Co., Ltd. BISOMAC308 1Phase&3Phase MM2015/9 KH-2015001
STEP 2 Connection of Power Supply
CAUTION
Use electric power source and power cable suitable for BISOMAC308.
When electric power source not suitable to specifications is used, it may heat up and
damage the cable etc., and equipment may no longer operate normally.
A
Connect the AC Power Plug of the BISOMAC308 to power distribution board.
Please check the types of connector.
The types of female connector and the cover are shown below.
1 Phase: HBL2323 (Maker: HUBBEL)
3 Phase: HBL2423 (Maker: HUBBEL)
Cover: HBL6032 (Maker: HUBBEL)
B
Necessary power per units is shown below.
Power of Each Mode
l
11.5A
9.0A
Model
1P-1000L
3P-1000L
1P-1258L
3P-1258L
If pair of hoists is used on the same platform, install “Y” electric supply yoke in the
power line to provide power to each hoist.
C
Ensure that the Emergency Stop Button of the BISOMAC308 and the interlock
of the Safety Devices are reset.
D
Ensure that current capacity and size of circuit fuse is adequate, refer to
specification in section 2.
E
Check if connector has any sign of deterioration.
Picture. 1