5.3.5
MANUAL STABILISER RECOVERY
IMPORTANT: ALWAYS STOW ALL OF THE BOOMS BEFORE USING THIS
FUNCTION. FAILURE TO DO THIS CAN RESULT IN SERIOUS INJURY OR
DEATH!
Note; Two persons are required for this procedure.
To manually recover the stabilisers in the event
of loss of power, ensure the Diverter Valve handle is turned towards the operator (see Section 5.3.2)
and both the CT17 Tap (red) and CT20 Tap (gold) are fully closed. Next either push the Stabiliser
Override fully in and hold, or pull fully out and hold. Now use the Booms Hand Pump to operate the
stabiliser function. The push or pull function of the Stabiliser Overrides determine whether the
stabilisers are deployed or retracted. The two Stabiliser Overrides operate either the left or right
stabiliser and are located in both ends of the chassis by removing the end covers. Return the diverter
valve handle to booms position (facing right) to allow canopy to close. This ensures that the hand
pump always defaults to ‘booms’ position when needed’.
5.4
INCIDENT NOTIFICATION
It is a mandatory requirement that any accident or incident involving a Niftylift is reported by telephone
directly to Niftylift, regardless of whether any party received injury or property was damaged. Failure to
do so may render any warranty on the machine void.