C. TROUBLESHOOTING
Problem
Solution
Pilots not lighting
❏
Check that broiler is plugged in, gas valve is
open and broiler is turned on
❏
Manually light
❏
Check for ignition
❏
Check for clogged pilot
Burners not
lighting
❏
Check for gas pressure, if there is pressure,
use the manual lighting procedure
❏
If no gas pressure, call for service
❏
Check for proper burner installation
❏
Check for plugged burner orifices
❏
Check for plugged pilot burner
Pilot not staying lit
❏
Call for service as thermocouple may need
replacing
Broil chain jams
❏
Check:
__ For sag in the chain (Chain may need a
link removed)
__ For an obstruction
9
Always verify that the broiler is properly assembled, the hood is on, gas valve open and broiler is plugged in.
Nieco Corporation - Model N1535
Product not cooking to
proper temperature in
cookouts
❏
Adjust cook time
❏
Check that broiler is calibrated properly
❏
Check that all burners are lit
❏
Check that all parts are installed correctly,
and that lower burner holes are facing up
❏
Check that broiler is properly cleaned
and assembled
❏
Check ventilation
__ Make sure there isn’t excessive
exhaust or an air vent blowing on the
broiler