Nieco Corporation - Model N1535
B. INSTALLATION
B.1 Pre-Installation
Uncrate the broiler and inspect for shipping damage. Remove the tape securing the machine parts, and
install the parts in their proper location. If there are obvious or concealed damages to any part of the
broiler, please contact your freight carrier. The factory warranty does not cover freight damage.
B.2 Mounting
B.2.1
Remove all parts from the broiler.
B.2.2
Lift broiler onto stand. NOTE: The cross bar on the base of the stand should be on the
discharge (back side) end of the broiler.
B.2.3
Use the supplied nuts and bolts to bolt the frame of the broiler to the stand.
B..2.4
Follow the steps outlined in the manual to reassemble the broiler.
B.3 Leveling
The grease drain system is based on a gravity-flow design. Therefore, it is extremely important to level
the broiler during installation.
B.4 Hood Requirements
This appliance must be installed under a ventilation hood of adequate size and the following minimum
capacity:
Model
SCFM
N1535
600
Do not obstruct the flow of combustion and ventilation air. An adequate air supply must be available for
safe and proper operation.
B.5 Clearance
For proper installation the minimum required clearance from combustible construction and walls is 12”
(305 mm) from all sides of the broilers. The minimum required clearance from non-combustible construc-
tion and walls is 0” (0 mm) from all sides of the broiler. Keep appliance area free from combustibles.
Check with local authorities (building and fire) for standards and requirements for wall and floor con-
struction to comply with your local codes.
REQUIRED for
installation near
combustible walls
and construction
REQUIRED for installa-
tion near non-com-
bustible walls and
construction
RECOMMENDED by
Nieco for proper disas-
sembly and service
Back of broiler
Sides of broiler
Front of broiler
(Feed end)
CAUTION
SEVERE FIRE HAZARD. Follow local fire and building codes for non-combustible construc-
tion. Failure to do so could result in a fire hazard. If unsure of your construction, follow mini-
mum clearances for combustible construction.
REQUIRED AND RECOMMENDED CLEARANCES
12” (305 mm)
12” (305 mm)
12” (305 mm)
24” (610 mm)
0” (0 mm)
0” (0 mm)
0” (0 mm)
12” (305 mm)
12” (305 mm)