This parameter displays the total number of receive data late events; each data late event will
increment the count by 1. The parameter value will wrap over to zero.
A data late event occurs when a cyclic data packet is received after the 'process at' time specified in
the packet.
A reset of the configuration will clear this count.
The count can be sampled by a user application in order to detect change since the last sample;
this enables custom reaction to a data late event occurring on a synchronous cyclic receive link
which has a received a message containing a time that is now in the past irrespective the defined
action for the link.
Used to select Tx1 as a standard or synchronous cyclic link.
This parameter is used to set the link number (1 to 255) for the Tx1 link.
S.10.009
Data Late Count
Minimum
0
Maximum
65535
Default
None
Units
None
Type
16 Bit Volatile
Update Rate
1 ms
Display Format
None
Decimal Places
0
Coding
RO, PT, NC, ND, BU
S.10.010
Tx1 Link Profile
Minimum
0
(Display: Std)
Maximum
1
(Display: Sync)
Default
0
(Display: Std)
Units
None
Type
8 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, Txt
Value
Text
Description
0
Std
Standard link
1
Sync
Synchronized link
S.10.011
Tx1 Link Number
Minimum
0
Maximum
255
Default
0
Units
None
Type
8 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, BU