background image

1

㻥㻝㻤㻠㻝㻭

㻿㼠㼍㼚㼐㼍㼞㼐㻌㼕㼚㼜㼡㼠㻌㼟㼑㼞㼕㼑㼟

㻰㼕㼒㼒㼑㼞㼑㼚㼠㼕㼍㼘㻌㼕㼚㼜㼡㼠㻌㼟㼑㼞㼕㼑㼟

FEATURES:

Multiple purpose digital tachometer measures

  optional, liner, and

fl

owratespeeds. Ifdesired, this 

  unit can also function as an elapse time counter or 

  ratiometer. 

An insertion of new cassette type adapter

  increases functions.

(CASSETTE TYPE OPTIONAL UNIT)

All functions are easily set via front panel keys.

Easy mounting, no brackets or screws are required.

Any AC voltage between 85 and 264V will power to

  DT-5TXAR.(DC powered DT-5TXDR: DC9 to 35V)

 Introduction

 Safety Requirements

Thank you for purchasing SHIMPO's Digital Tachometer DT-5TXR/ DT-5TFR. For instructions to use this product

properly and optimally for a long period of time, please be sure to read this manual thoroughly before use.

After reading, please store this manual in a safe place for future reference.

When you purchase the product with optional equipment:

     Please refer to the optional equipment's operation manual.

The following requirements are very important for this product's correct and safe use. 

After reading, be sure to store this manual in a safe, convenient place where operators can always refer to it easily.

㻰㼀㻙㻡㼀㼄㻾 㻛㻰㼀㻙㻡㼀㻲㻾

㻵㻺㻿㼀㻾㼁㻯㼀㻵㻻㻺㻌㻹㻭㻺㼁㻭㻸

㻿㼜㼑㼑㼐㼙㼑㼠㼑㼞䡡㻱㼘㼍㼜㼟㼑㼐㻌㼠㼕㼙㼑㼏㼛㼡㼚㼠㼑㼞䡡㼀㼕㼙㼑㻌㼣㼕㼐㼑㻌㼙㼑㼠㼑㼞䡡㻲㼘㼛㼣㼙㼑㼠㼑㼞

㻰㼕㼓㼕㼠㼍㼘㻌㼀㼍㼏㼔㼛㼙㼑㼠㼑㼞㻌

Caution

Electric Shock

Be sure to turn the power OFF when wiring as well 

as inspecting the unit. 

Otherwise, an electric shock can be caused.

DO NOT block the unit’s ventilation holes located on 

the sides of the unit. Also, DO NOT put any foreign 

matters inside the unit through these holes.

Otherwise, abnormal heat generation or equipment 

malfunction can be caused.

DO NOT touch the unit with wet (or sweaty) hands 

for wiring and inspection. 

Otherwise, an electric shock can be caused.

In case of assembling the 

fi

rst option to DT-5TXR unit 

body after purchasing,

please note that only the options with “R” at the foot 

of model name can be connected to the unit.

Operating Environment

POWER

Make sure AC voltage is between 85 and 264V.(DC powered DT-5TXDR:DC9 to 35V)

When installing unit,keep power and sensor wires separate.

INPUT SIGNAL WIRE

Connection wiring from sensors shall not be kept in the same or parallel conduit or cable as the power 

source, power or high voltage cables to avoid noise which may cause mulfunction.

Use shielded wire for input power connections in the shortest possible metal conduit.

TERMINAL

After inserting wires tighten terminals securely.

OPERATING ENVIRONMENT

DO NOT install this unit in the following locations:

Where the unit is exposed to direct sunlight, or where the ambient temperature exceeds a range of 0 - 45

Υ

.

Where the relative humidity exceeds a range of 35 - 85% and where the temperature changes quickly causing 

condensation.

Where corrosive and/ or 

fl

ammable gases are present.

Where levels of dust, salinity, and/ or ferric substance presence are high.

Where direct vibration or impacts can be applied to the unit.

Where the unit can easily be in

fl

uenced by noises (including static electricity).

Summary of Contents for SHIMPO DT-5TFR

Page 1: ...Also DO NOT put any foreign matters inside the unit through these holes Otherwise abnormal heat generation or equipment malfunction can be caused DO NOT touch the unit with wet or sweaty hands for wir...

Page 2: ...Option Power Requirement Input Type HH High set point 2 output H High set point 1 output L Low set point 1 output LL Low set point 2 output For combinations of the above mentioned output levels refer...

Page 3: ...ped only terminal block for the 1st optional equipment or connector for the 2nd optional equipment can be viewed from outside of this unit Rear Note When the connector is attached a 30 mm or more spac...

Page 4: ...unit to the panel with the attachment screws The specified torque to fasten the screws is 6 5kgf cm or less Place the unit horizontally and then insert it into the panel s attachment opening Push the...

Page 5: ...ion Be sure to use sealed wires for input connection or install them in a metal conduit as well as to keep the wires as short as possible DT 5TXR Terminal block connection diagram Note When using an N...

Page 6: ...sensor s connection wires together with strong electric cables power cable high voltage cable etc via bundling wiring in parallel or installing them in one conduit Otherwise noise is sent via a sig n...

Page 7: ...ther When the actual rpm can be checked measured the following easy method field adjustment can be used for the settings The field adjustment does not require complicated calculations Via this functio...

Page 8: ...are not necessary the default values values shown above designated upon shipping can be used as is Note 1 The high set point 2 value is displayed on the sub display A and the low set point 2 value on...

Page 9: ...e is 1000 output is turned ON and when it is 990 OFF About Display Use Function 5 Sub display s display pattern selection to select the desired display pattern from the following three Display pattern...

Page 10: ...n about the parameter function refer to page 8 For detailed information about the function refer to page 8 Note 1 The high set point 2 value is displayed on the sub display A and the low set point 2 v...

Page 11: ...he low set point 2 value on the sub B display The display system is designated via parameter 3 value to be dis played The sub displays do not display the colon Note 2 Function 10 can be set up only wh...

Page 12: ...Note 3 Functions 11 to 14 can be set up when the first optional equipment DOP FVTR or the second optional equipment DOP FVC has been installed bout Scaling Parameter 3 Scaling factor is a value obtai...

Page 13: ...hen a measuring value is smaller than the low set point 1 value Lights up when a measuring value is smaller than the low set point 2 value Designates via function 5 see page 8 Designates via function...

Page 14: ...nd DT 5TFR this mode is used to perform self diagnosis of the internal circuit LED display test key entry test The mode number is 99 Test Type Checks if the main display s LED is functioning correctly...

Page 15: ...display s first digit In the same manner press each key and 1 is displayed on the related display digit LED There is no entry test for the SET and MOD keys LED related to each key is as follows Main d...

Page 16: ...mber of pulse is one per revolution When display value is 46 8m min at 1200rpm analog output signal is 10V Minimum out put signal is 0V and update time is same as display cycle Other Parameter and Fun...

Page 17: ...f assembling the first option to DT 5TXR unit body after purchasing please note that only the options with R at the foot of model name can be connected to the unit For both DT 5TXR and DT 5TFR if you...

Page 18: ...fications and wiring method for the correct use Specifications The user must perform cable connection Wiring Connector connection HOLD input circuit ENABLE input circuit Output circuit Measured data H...

Page 19: ...and DT 5TFR if you purchase a model with optional equipment be sure to check its model specifications and wiring method for the correct use This operation manual is applicable to the following models...

Page 20: ......