FEATURES:
●
Multiple purpose digital tachometer measures
optional, liner, and
fl
owratespeeds. Ifdesired, this
unit can also function as an elapse time counter or
ratiometer.
●
An insertion of new cassette type adapter
increases functions.
(CASSETTE TYPE OPTIONAL UNIT)
●
All functions are easily set via front panel keys.
●
Easy mounting, no brackets or screws are required.
●
Any AC voltage between 85 and 264V will power to
DT-5TXAR.(DC powered DT-5TXDR: DC9 to 35V)
Introduction
Safety Requirements
Thank you for purchasing SHIMPO's Digital Tachometer DT-5TXR/ DT-5TFR. For instructions to use this product
properly and optimally for a long period of time, please be sure to read this manual thoroughly before use.
After reading, please store this manual in a safe place for future reference.
凜
When you purchase the product with optional equipment:
Please refer to the optional equipment's operation manual.
The following requirements are very important for this product's correct and safe use.
After reading, be sure to store this manual in a safe, convenient place where operators can always refer to it easily.
㻰㼀㻙㻡㼀㼄㻾 㻛㻰㼀㻙㻡㼀㻲㻾
㻵㻺㻿㼀㻾㼁㻯㼀㻵㻻㻺㻌㻹㻭㻺㼁㻭㻸
㻿㼜㼑㼑㼐㼙㼑㼠㼑㼞䡡㻱㼘㼍㼜㼟㼑㼐㻌㼠㼕㼙㼑㼏㼛㼡㼚㼠㼑㼞䡡㼀㼕㼙㼑㻌㼣㼕㼐㼑㻌㼙㼑㼠㼑㼞䡡㻲㼘㼛㼣㼙㼑㼠㼑㼞
㻰㼕㼓㼕㼠㼍㼘㻌㼀㼍㼏㼔㼛㼙㼑㼠㼑㼞㻌
Caution
Electric Shock
Be sure to turn the power OFF when wiring as well
as inspecting the unit.
Otherwise, an electric shock can be caused.
DO NOT block the unit’s ventilation holes located on
the sides of the unit. Also, DO NOT put any foreign
matters inside the unit through these holes.
Otherwise, abnormal heat generation or equipment
malfunction can be caused.
DO NOT touch the unit with wet (or sweaty) hands
for wiring and inspection.
Otherwise, an electric shock can be caused.
In case of assembling the
fi
rst option to DT-5TXR unit
body after purchasing,
please note that only the options with “R” at the foot
of model name can be connected to the unit.
Operating Environment
■
POWER
Make sure AC voltage is between 85 and 264V.(DC powered DT-5TXDR:DC9 to 35V)
When installing unit,keep power and sensor wires separate.
■
INPUT SIGNAL WIRE
Connection wiring from sensors shall not be kept in the same or parallel conduit or cable as the power
source, power or high voltage cables to avoid noise which may cause mulfunction.
Use shielded wire for input power connections in the shortest possible metal conduit.
■
TERMINAL
After inserting wires tighten terminals securely.
■
OPERATING ENVIRONMENT
DO NOT install this unit in the following locations:
Where the unit is exposed to direct sunlight, or where the ambient temperature exceeds a range of 0 - 45
Υ
.
Where the relative humidity exceeds a range of 35 - 85% and where the temperature changes quickly causing
condensation.
Where corrosive and/ or
fl
ammable gases are present.
Where levels of dust, salinity, and/ or ferric substance presence are high.
Where direct vibration or impacts can be applied to the unit.
Where the unit can easily be in
fl
uenced by noises (including static electricity).