NE200&300 Quick Start Guide
25
Code
Description
Setting range
Default
Modify
Modbus
Address
3: PULSE setup
4: Communication
5:MS (Multi-step) Speed
6: PLC
7: PID
8: Keypad potentiometer
F0.04
Frequency
reference2
(Freq. ref.2)
1: Al1
2: Al2
1
○
0104H
3: PULSE setup
4: Communication
5:MS (Multi-step) Speed
6:
Reserved
7: Reserved
8: Keypad potentiometer
F0.05
Frequency
setting
selection
0:Freq. ref.1
0
○
0105H
1:Freq. ref.2
2: Freq. ref.1+ Freq. ref.2
3: Switch between Freq.
ref.1 & Freq. ref.2 by
terminal
4: Switch between (Freq.
ref.1+ Freq. ref.2) & Freq.
ref.1 by terminal
5:MIIN (Freq. ref.1, Freq.
ref.2)
6:MAX (Freq. ref.1, Freq.
ref.2)
F0.06
UP/DOWN
Preset freq.
0~ Max frequency
50.00Hz
○
0106H
F0.07
Terminal UP/
DOWN rate
0.01~ 50.00Hz/s
1.00Hz/s
○
0107H
F0.08
UP/DOWN
function
source select
0: Keypad and terminal
1
○
0108H
1: Keypad
2: Terminal
F0.09
UP/DOWN
data saving
0: Be saved in power
failure
0
○
0109H