33
PARAMETER-SETTING INTERFACE AND OPTIONS
POWERDRIVE MD2R Installation guide
4948 - 2017.11 / d
en
• Architecture
From the welcome screen, press the
button to access the
main page of the parameter-setting interface, consisting of 5
touch-sensitive buttons:
- Information
: Can be used to obtain information very quickly
about the drive, the fieldbus option, the parameter-setting
interface, and can also be used to select the language.
- Read mode
: Is used to display the status of the drive when
stopped or in operation, as well as its main operating data.
- Parameter setting
: Used for reading and/or modifying all
the drive parameters, as well as setting the date and time on
the display.
- Trip history
: Gives a quick overview of the last 10 drive
trips.
-
: This button is accessible on all screens in factory-set
configuration and is used to give a stop command (can be
disabled).
At any time and regardless of the screen displayed, the
button can be used to return to previous pages, as far as the
interface main page.
For further information, see the commissioning manual
ref. 4617.
MDX-SOFT
The MDX-SOFT enables parameter setting or supervision of
the
POWERDRIVE MD2R
from a PC. Numerous functions
are available:
- Fast commissioning
- File saving
- Comparison of 2 files or one file with the factory settings
- Printing of a complete file or differences compared to the
factory settings
- Supervision
- Diagnostics
To connect the PC to the POWERDRIVE MD2R, use an
"MDX-USB Isolator" isolated USB cable.
This software can be downloaded from the web at the
following address: http://www.emersonindustrial.com/
POWERDRIVE MD2R
can be set via the USB connector,
even if the drive is not powered.
Attention. In this case, options modules will not be powered
and settings will not be saved. To make an option module
setting / backup , it is necessary to provide an auxiliary power
supply.
Special settings
Refer to the installation manual of (ref. 4617) for details on
settings.
• Clogged filter alarm
POWERDRIVE MD2R
has an "overtemperature" alarm
(# 10.18) which warns the user when the internal temperature
of the product reaches 60°C or when a power module
overheats.
To set a different alarm treshold, you can use the following
settings:
Using comparator 3:
#12.63
=
7.55
(source = control board temperature)
#12.64
=
60
(threshold = 60 ° C)
#12.65
=
2
°C (hysteresis)
#12.65
=
0
To display information on the HMI of the drive:
#12.67
=
10.54
(User Alarm 1)
To adress information to a digital output (eg. DO1)
# 8.26
=
12.61
(DO1 assigned to comparator 3)
Reminder:
POWERDRIVE MD2R
filters are washable and
must be kept clean. See § 7 - Maintenance