NC-AD300E Manual
- 29 -
Link Code (SLC), the logical link number, must be consistent with the SS7 equipment on other side.
Click to Edit.
Business types, currently supports two kinds of TUP and ISUP. Click to select.
Connection method, specify the link where to connect. Click to select.
No,
that there is no link connection, this link is invalid.
Hand Link,
the link is from E1.
Netclient,
get ss7 link
from SWGIP
NetServer,
forward SS7 link data through Ethernet (service side).
NetworkServerAndClient,
including "NetClient" and "netserver" for cascading multiple
devices
SGW,
connection from the PCM link, and transfer it to network for secondary development.
Link time slot, which time slots have the SS7 link.
Signaling point code-bit length, specify the length of the signaling point codes. Usually 24-bit for
domestic and international use 14-bit.
Signaling point code, SS7 signaling code, in the format XXX-XXX-XXX.
Backup link slot, If use 2 SS7 link to back each other, time slot for the back SS7 link.(load sharing).
Caller category, caller attributes, caller screening, caller display, called attributes, specify the
number of attributes called the primary, usually select the default value.
MfcValdelay, if calling number is received by-bit, over this time the receiving will be finished.
Usage pattern: usually choose "normal mode." "Signaling Collection" and "high-impedance
recording" in and line monitoring of the
use of high barrier from the need for external devices can
be collected signaling, monitoring recording.
When the check the "ring-back does not pass through", the device will provide their own ring back tone,
rather than pass through the next level.
After completion of editing, write to ROM, restart the device for effective.
5.2.4.4 V5.2 signaling
When using V5.2 signaling, the need to set the link parameters of V5. AD300E maximum support
One dirction , two links. Goes to "V5.2 signaling" and see belowparameters.
V5 variable and V5ID are the main parameters that must be consistent with the other side.