“Electromagnetic compatibility” Directive:

Special warnings regarding the fitness of use of this product in relation to the “Electromagnetic compatibility” Directive.

This product has been subjected to electromagnetic compatibility tests in the most critical situations of use and in the configurations specified 

in this instruction manual and in combination with the items in the Nice S.p.A. product catalogue.

If the product is used in unspecified configurations or with other unspecified products, the electromagnetic compatibility may not be guar

-

anteed; the use of the product is prohibited in such circumstances until the installer has verified compliance with the specified requirements 

of the directive.

Installation criteria and special warnings in connection with essential requirements

When installed correctly, this product meets the essential requirements laid down in Regulation No. 305/2011 according to the requirements 

in harmonised standard EN 13241-1, as indicated in Table 1 and in the European directive on “Machinery” 2006/42/EC.

Release of dangerous substances:

The product does not contain and/or release hazardous substances in accordance with the requirements of EN 13241-1, 4.2.9 and accord

-

ing to the list of substances on the website of the European Community

Special warning to ensure the continued compliance with the requirement – It is essential that the other materials used in the installation, 

such as electrical cables, comply with this requirement.

Safe opening for horizontally

 moving doors: the product does not cause uncontrolled movements.

Special warnings to ensure continued compliance of the requirements:

- Install the product carefully following all the instructions described in Chapter “2 - Installation” and Chapter “4 - Testing and commissioning”.

- Ensure that a maintenance schedule is organised which scrupulously complies with all the provisions in the Chapter “Maintenance 

Schedule”.

As regards the risks of crushing and impact, the sliding closures

 are protected by means of one of these three methods:

1

 - For operation with “hold-to-run command” (man present): as specified in EN 12453, point 5.1.1.4. In this case the command button 

must be placed in view of the automation and if it is accessible to the public, the command button must not be available to them, e.g. 

use only with a key switch.

2

 - For “Semi-automatic” operation: through the use of an active sensitive edge for limiting the forces as specified in EN 12453, paragraphs 

5.1.1.5 and 5.1.3.

3

 - For “automatic” operation: through the use of an active sensitive edge for limiting the forces as specified in EN 12453, paragraphs 5.1.1.5 

and 5.1.3; in this case, at least one pair of photocells must be installed as shown in Fig. 2.

Summary of Contents for TUB4000

Page 1: ...installazione e l uso FR Instructions et avertissements pour l installation et l utilisation ES Instrucciones y advertencias para la instalaci n y el uso DE Installierungs und Gebrauchsanleitungen und...

Page 2: ......

Page 3: ...airs or adjustments are necessary because a failure with the installation or an incorrectly balanced automated system may lead to injury The packing materials of the product must be disposed of in com...

Page 4: ...he website of the European Community Special warning to ensure the continued compliance with the requirement It is essential that the other materials used in the installation such as electrical cables...

Page 5: ...kg or up to 30 m long according to the data shown in Table 1 below TABLE 1 Length of leaf in metres Maximum cycles hour Up to 5 42 5 10 21 10 15 14 15 20 10 20 25 8 25 30 7 0 0 5 10 15 20 25 30 35 40...

Page 6: ...t piece of the rack on the pi nion and check that the beginning of the rack corresponds to the beginning of the leaf Make sure that there is at least 2 3 mm of play between the rack and the pinion the...

Page 7: ...ecessary in particular applications See the instructions manual for the advised type of connection if there is more than one edge Note 5 Special devices which enable connection even when the leaf is m...

Page 8: ...6 English EN V W U L1 L2 L3 1 2 3 NDA040 4 5 6 1 2 3 A Neutral wire from the supply plug...

Page 9: ...Check that all the instructions in the Installation warnings chapter have been rigorously complied with 2 Using the control devices transmitter push button key switch etc test the Opening Closing and...

Page 10: ...essories for other brands contact the motor manufacturer 5 7 11 m Cable for FLASHING LIGHT with aerial 2 x 1 mm2 for 230 V AC flashing light RG58 type shielded cable aerial 10 m PHOTOCELL cable 4 x 0...

Page 11: ...nose pliers 03 Insert the jumper 1 x 230 V 04 Re insert the top cover 7 4 Description of the electrical connections Fig 14 power supply safety and control devices and accessories You can connect contr...

Page 12: ...ut for the earth connection for the control unit and motors IMPORTANT We DO NOT recommend that you connect any device or accessory not mentioned in this instruction manual The manufacturer declines al...

Page 13: ...only for motors with mechani cal limit switches leave uncon nected with motors which have electronic limit switches LIMIT SWITCH mechanical limit switch STOP STOP terminal used for 8K2 safety edge or...

Page 14: ...he position acquisition phase or by using the Oview programmer Command No 3 Open Command No 4 Close Command No 5 Stop Command No 6 Step by Step Condominium Command No 7 Step by Step High priority Comm...

Page 15: ...ection with that of the closing limit switch at the LIMIT SWITCH terminal Fig 14 The position recognition phase can be repeated at any time also after the installation 7 11 Operating modes CAUTION If...

Page 16: ...ng the testing phase as described below refers to a typical system 1 Check that all the instructions in the Installation warnings chapter have been rigorously complied with 2 Release the motor Check t...

Page 17: ...sages to identify their status and faults The following table describes the various alarm signals according to the type of problem These alarm signals are provided by appropriate flashes of the green...

Page 18: ...g SAFETY LED DIAGNOSTICS Signal Cause Solution On Correct operation Off Safety chain open The safety chain is made up of the series of inputs ALT Stop via button motor thermal protection motor release...

Page 19: ...slation in your area or return the product to the retailer when purchasing an equivalent product CAUTION Local legislation may include the application of heavy fines in the event of improper disposal...

Page 20: ...ble to partly completed machinery Annex II part 1 section B In addition the product conforms to the following directive in accordance with the provisions applicable to partly completed machinery Direc...

Page 21: ...ough the wired controls It is not possible to send commands via radio If the safety devices are out of order arrange to repair the automation as soon as possible Releasing and locking the gearmotor ma...

Page 22: ......

Reviews: