PRODUCT DISPOSAL

This product constitutes an integral part of the automation and, therefore, must be disposed of together with it.

Similarly to the installation phase, once the product reaches the end of its useful life, the disassembly and scrapping operations must be performed by qualified 

personnel.

This product is made of various types of materials, some of which can be recycled while others must be scrapped. Seek information on the recycling and disposal 

systems envisaged by local regulations in your area for this product category.

CAUTION!

 – Some parts of the product may contain polluting or hazardous substances which, if released into the environment, constitute serious environmental 

and health risks.

As indicated by the adjacent symbol, the product may not be disposed of together with domestic waste. Sort the materials for disposal, acco 

ding to the methods envisaged by current legislation in your area, or return the product to the retailer when purchasing an equivalent product. 

CAUTION!

 – Local legislation may include the application of heavy fines in the event of improper disposal of this product.

13

TECHNICAL SPECIFICATIONS

WARNINGS:

 

 

All technical specifications stated herein refer to an ambient temperature of 20° C (± 5° C). • Nice S.p.A. reserves the right to apply modifications 

to products at any time when deemed necessary, maintaining the same intended use and functionality.

Type

Electromechanical self-braking gear motor for the automatic movement of sliding gates for industrial use, 

complete with electronic control unit DPRO500 

Pinion

Z = 18; Module = 6; Pitch = 18.8

Peak thrust

216 Nm

Nominal torque

65 Nm

Nominal torque speed

0.16m/s (9,50m/min)

Operating limits

TUB4000 is generally capable of automating gates up to 4000 Kg in weight and 30 m in length.

Power supply

3~ 400V ac +/-10%; 50Hz.

Max. absorbed power

580 W

Nominal absorption

1,6 A

Insulation class

1 (a safety earthing system is required)

Operating temperature

-20°C ... 55°C

Protection level

IP 54

Dimensions (mm)

580 x 480 x 240

Weight

60 kg

Summary of Contents for TUB4000

Page 1: ...installazione e l uso FR Instructions et avertissements pour l installation et l utilisation ES Instrucciones y advertencias para la instalaci n y el uso DE Installierungs und Gebrauchsanleitungen und...

Page 2: ......

Page 3: ...airs or adjustments are necessary because a failure with the installation or an incorrectly balanced automated system may lead to injury The packing materials of the product must be disposed of in com...

Page 4: ...he website of the European Community Special warning to ensure the continued compliance with the requirement It is essential that the other materials used in the installation such as electrical cables...

Page 5: ...kg or up to 30 m long according to the data shown in Table 1 below TABLE 1 Length of leaf in metres Maximum cycles hour Up to 5 42 5 10 21 10 15 14 15 20 10 20 25 8 25 30 7 0 0 5 10 15 20 25 30 35 40...

Page 6: ...t piece of the rack on the pi nion and check that the beginning of the rack corresponds to the beginning of the leaf Make sure that there is at least 2 3 mm of play between the rack and the pinion the...

Page 7: ...ecessary in particular applications See the instructions manual for the advised type of connection if there is more than one edge Note 5 Special devices which enable connection even when the leaf is m...

Page 8: ...6 English EN V W U L1 L2 L3 1 2 3 NDA040 4 5 6 1 2 3 A Neutral wire from the supply plug...

Page 9: ...Check that all the instructions in the Installation warnings chapter have been rigorously complied with 2 Using the control devices transmitter push button key switch etc test the Opening Closing and...

Page 10: ...essories for other brands contact the motor manufacturer 5 7 11 m Cable for FLASHING LIGHT with aerial 2 x 1 mm2 for 230 V AC flashing light RG58 type shielded cable aerial 10 m PHOTOCELL cable 4 x 0...

Page 11: ...nose pliers 03 Insert the jumper 1 x 230 V 04 Re insert the top cover 7 4 Description of the electrical connections Fig 14 power supply safety and control devices and accessories You can connect contr...

Page 12: ...ut for the earth connection for the control unit and motors IMPORTANT We DO NOT recommend that you connect any device or accessory not mentioned in this instruction manual The manufacturer declines al...

Page 13: ...only for motors with mechani cal limit switches leave uncon nected with motors which have electronic limit switches LIMIT SWITCH mechanical limit switch STOP STOP terminal used for 8K2 safety edge or...

Page 14: ...he position acquisition phase or by using the Oview programmer Command No 3 Open Command No 4 Close Command No 5 Stop Command No 6 Step by Step Condominium Command No 7 Step by Step High priority Comm...

Page 15: ...ection with that of the closing limit switch at the LIMIT SWITCH terminal Fig 14 The position recognition phase can be repeated at any time also after the installation 7 11 Operating modes CAUTION If...

Page 16: ...ng the testing phase as described below refers to a typical system 1 Check that all the instructions in the Installation warnings chapter have been rigorously complied with 2 Release the motor Check t...

Page 17: ...sages to identify their status and faults The following table describes the various alarm signals according to the type of problem These alarm signals are provided by appropriate flashes of the green...

Page 18: ...g SAFETY LED DIAGNOSTICS Signal Cause Solution On Correct operation Off Safety chain open The safety chain is made up of the series of inputs ALT Stop via button motor thermal protection motor release...

Page 19: ...slation in your area or return the product to the retailer when purchasing an equivalent product CAUTION Local legislation may include the application of heavy fines in the event of improper disposal...

Page 20: ...ble to partly completed machinery Annex II part 1 section B In addition the product conforms to the following directive in accordance with the provisions applicable to partly completed machinery Direc...

Page 21: ...ough the wired controls It is not possible to send commands via radio If the safety devices are out of order arrange to repair the automation as soon as possible Releasing and locking the gearmotor ma...

Page 22: ......

Reviews: