6.10 - “Move anyway” function
If one or more safety devices do not work properly or they are out of order, this feature allows you to control the motor in the ‘Hold-to-run’ mode
all the same (for details see the chapter ‘User Manual’).
6.11 - Diagnostics
Some devices are display messages to identify their status and faults.
6.11.1 - Control unit signals
The green and red LEDs on the control unit produce special signals to report normal operation and any anomalies.
Table 10 lists the signals:
Table 10
LED OK /BB
Cause
Solution
Off
Fault
- Check for presence of power supply; check that the fuses are not blown: in this case, identify the cause
of the fault and then replace them with versions with the same specifications.
- Check for short-circuited cables.
- Check whether the control unit thermal cutout has tripped and switched it off. Wait for 1 minute and check
whether it starts up again.
On for more
than 20 sec-
onds.
Fault
A serious malfunction has occurred; try switching off the control unit for 20-30 seconds; if the condition
persists, it means there is a malfunction and the circuit board must be replaced.
Flashing light
Ok
Normal control unit operation.
Double flash
The status
of the inputs
has changed
This is normal when there is a change in one of the inputs: SbS, STOP, OPEN, CLOSE, triggering of photo-
cells, or the radio transmitter is in use or the PROG switch is on.
Series of
flashes with
pause
Diagnostics
It is the same signal present on the courtesy light (SPYLIGHT) (see Table 11).
Description of Programming LEDs with PROG selector positioned on the left
I
O
I
O
L1 LED
Description
Off
During normal operation the device indicates ‘Automatic Closing’ is not active.
On
During normal operation the device indicates ‘Automatic Closing’ is active.
Slow flashing
• Function programming in progress.
• If it flashes together with L2, it means that the user must carry out the device acquisition phase (see section 5.3).
L2 LED
Description
Off
During normal operation the device indicates ‘Close after photo’ is not active.
On
During normal operation the device indicates ‘Close after photo’ is active.
Slow flashing
• Function programming in progress.
• If it flashes together with L1, it means that the user must carry out the device acquisition phase (see section 5.3).
L3 LED
Description
Off
During normal operation the device indicates ‘Always close’ is not active.
On
During normal operation the device indicates ‘Always close’ is active.
Slow flashing
• Function programming in progress.
• If it flashes together with LED L4, the user must run the learning phase of the opening and closing positions (section 5.4).
LED L4
Description
Off
During normal operation, the device indicates ‘Standby’ is not active.
On
During normal operation, the device indicates ‘Standby’ is active.
Slow flashing
• Function programming in progress.
• If it flashes together with LED L3, the user must run the learning phase of the Opening and Closing positions (section 5.4).
LED L5
Description
Off
During normal operation the device indicates ‘Test STOP 8K2’ is not active.
On
During normal operation the device indicates ‘Test STOP 8K2’ is active.
Slow flashing
Function programming in progress.
LED L6
Description
Off
During normal operation the device indicates ‘Lock command buttons’ is not active.
On
During normal operation the device indicates ‘Lock command buttons’ is active.
Slow flashing
Function programming in progress.