background image

– English

IMPORTANT SAFETY INSTRUCTIONS

 
WARNING

To reduce the risk of severe injury or death:

• READ AND FOLLOW ALL INSTRUCTIONS.

Never let children operate or play with door controls. Keep the remote control away from children.

• Always keep the moving door in sight and away from people and objects until it is completely closed. NO ONE SHOULD CROSS 

THE PATH OF THE MOVING DOOR.

• For vertically moving doors: NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR.
• For horizontally moving doors: NEVER GO THROUGH A STOPPED, PARTIALLY OPEN DOOR.

Test door opener monthly. The garage door MUST reverse on contact with a 38-mm (1-1/2-inch) high object (or a 2 by 4 board 

laid flat) on the floor. After adjusting either the force or thelimit of travel, retest the door opener. Failure to adjust the opener 

properly increases the risk ofsevere injury or death.

• For vertically moving doors for products having an emergency release, when possible, use the emergency release only when 

the door is closed. Use caution when using this release with the door open. Weak or broken springs are capable of increasing 

the rate of door closure and increasing the risk of severe injury or death.

• KEEP GARAGE DOORS PROPERLY BALANCED. See user’s manual. An improperly balanced door increases the risk of severe 

injury or death.
- For vertically moving doors: have a qualified service person make repairs to cables, spring assemblies, and other hardware.
- For horizontally moving doors: have a qualified service person make repairs and hardware adjustments before installing the 

opener.

• Where possible, install the door operator 2.14 m (7 ft) or more above the floor. For products having an emergency release, 

mount the emergency release within reach, but at least 1.83 m (6 ft) above the floor and avoiding contact with vehicles to avoid 

accidental release.

• For operator systems equipped with an unattended operation feature, the following statement shall be included: “This operator 

system is equipped with an unattended operation feature. The door could move unexpectedly. NO ONE SHOULD CROSS THE 

PATH OF THE MOVING DOOR.”

• SAVE THESE INSTRUCTIONS.

Be careful when activating the manual unlocking device (manual manoeuvre), as an open door may fall suddenly due to weak or broken 
springs, or if it is unbalanced.

If the power cable is damaged, it must be replaced by the manufacturer or by an appointed servicing company or similarly qualified person 
in order to prevent any form of risk.

Summary of Contents for SPY800KCE/V1

Page 1: ...EN Instructions and warnings for installation and use SPY800KCE V1 Garage door opener Nice...

Page 2: ...parameters ADJUSTABLE PARAMETERS 17 5 7 External radio receiver SPYBOX B V1 only 19 5 7 1 Memorisation of radio transmitters 19 6 FURTHER DETAILS 20 6 1 Connecting an Oview 20 6 2 Adding or removing...

Page 3: ...sting and commissioning chapter Before proceeding with the product s installation check that all the materials are in good working order and suited to the intended applications ATTENTION In order to a...

Page 4: ...easing the risk of severe injury or death KEEP GARAGE DOORS PROPERLY BALANCED See user s manual An improperly balanced door increases the risk of severe injury or death For vertically moving doors hav...

Page 5: ...verhead doors with accessory SPA5 Protruding overhead doors with accessory SPA5 or with springs without SPA5 width height width height width height SPY800KCE V1 10ft 6in guide 3 2 m 16ft 4in 55 64 5 m...

Page 6: ...g to EN12604 private use 150 N maximum industrial business use 260 N maximum 4 2 125 105 260 3 B 0 15 3 4 0 400 mm 4 7 8 125 mm A 1 1 2 15 3 4 40 400 mm C 2 9 16 11 3 16 65 300 mm Fig 5 shows the loca...

Page 7: ...e strip CAUTION Be careful not to deform it 03 insert the strip into the rubber ex truded element 04 1 release the gearmotor with release cord 2 check that the gear wheel turns freely 3 insert the mot...

Page 8: ...on the control unit refer to Chapter 3 2 point 04 06 a unit positioned on the zone towards the door 1 press the side tabs 2 insert the terminal element into the guide 3 secure the terminal element wit...

Page 9: ...o wall using special screws not in cluded 1 4 6 mm B A 6 mm not included 10 Check the fixing positions Fig 4 1 apply the strikes supplied to the guide 2 position the guide 3 fasten the guide to the br...

Page 10: ...l guides 5 fix the brackets to the ceiling with special screws not included 1 4 6 mm 6 cut the two brackets exactly flush with the guide to prevent the motor carriage stopping during movement 7 fasten...

Page 11: ...t 7 13 32 20 m Reconfigurable input 24VDC It is factory configured as a NO input with Courtesy Light ON OFF operation SPYBOX B V1 4 STOP 2 x 20 AWG 2 x 0 5 mm2 65ft 7 13 32 20 m Input for the connecti...

Page 12: ...with a contact opening distance that permits com plete disconnection under the conditions dictated by overvoltage category III Before intervening on the system maintenance cleaning always disconnect...

Page 13: ...force private use 150 N maximum industrial business use 260 N maximum Clik 03 Put the motor carriage back 04 Using the key switch or radio transmitter or the control unit buttons test the opening and...

Page 14: ...sponsible for the commissioning serial number year of manufacture and CE mark 06 Prepare the declaration of conformity of the automation system and deliver it to the owner 07 Give the owner the user m...

Page 15: ...nly works with virgin memory After the initial flashing of the LEDs the control unit waits for the acquisition of the devices by making L1 L2 flash slowly Control unit quick set up only starts with th...

Page 16: ...arch procedure CAUTION During this procedure the control unit switches the internal relays to run a few functional tests CAUTION The device acquisition phase must be performed even if there is no devi...

Page 17: ...the function then acquire the devices with the 8K2 edge connected L6 Lock OPEN and CLOSE buttons Deactivates the operation of the OPEN and CLOSE buttons on the lid of the box when the switch is in 0...

Page 18: ...lev 100 CL lev 50 L8 OP lev 100 CL lev 75 L1 Disabled L2 OP lev 60 CL lev 60 Motor sensitivity L3 OP lev 60 CL lev 70 L6 low more force L4 OP lev 60 CL lev 80 high little force L5 OP lev 60 CL lev 90...

Page 19: ...eceiver in Mode 2 with the memorisation of the transmitter in Mode 2 see receiver man ual each button on the transmitter can be associated with one of the following commands on the control unit Key Co...

Page 20: ...he BlueBus and Stop or delete others that are already present see section 5 3 Bluebus Input The BlueBus system allows you to connect compatible devices using only two wires which carry both the power...

Page 21: ...the start of each manoeuvre To activate the 8K2 test mode you must enable the L5 parameter in the 1st level menu 6 4 Power for external devices If you want to power external devices proximity reader f...

Page 22: ...conds With the motor stationary the Courtesy Light can be switched on or off by pressing the STOP button from the dedicated Light input or through the Oview programmer for each command received the st...

Page 23: ...Figure Clik 2 1 3 5 4 ON 6 8 Solemyo System only for SPYBOX B V1 SPYBOX B V1 is designed to be powered with the Solemyo photovoltaic power system For connection to the control unit you must use the s...

Page 24: ...ameter of cable route hole on the motor carriage is 1 4 6 5 mm For the connection follow the instructions below 01 a connect the safety device refer to your instruction manual b remove the cover of th...

Page 25: ...escription Off During normal operation the device indicates Automatic Closing is not active On During normal operation the device indicates Automatic Closing is active Slow flashing Function programmi...

Page 26: ...ause If nec essary increase the value of the Motor Force or reduce the Obstacle detection sen sitivity value 4 flashes pause of 1 sec 4 flashes Activation of the STOP input At the start of or during t...

Page 27: ...ck that the product is being supplied 120 V mains power Check to see if the line fuse is blown if it is identify the reason for the failure and then replace the fuses with others having the same curre...

Page 28: ...lication of serious fines in the event of improper disposal of this product 9 9 MAINTENANCE CAUTION disconnect the power supply to the control unit and any backup battery before performing any task on...

Page 29: ...rature 20 C 55 C Protection class IP41 Maximum force 800N Nominal force 250N Maximum velocity 0 14 m s Limits of use See Chapter 1 and 2 Table 1 and 2 Courtesy light External SPYLIGHT Preparation for...

Page 30: ...30 English NOTE...

Page 31: ...r the system The final test the periodic maintenance operations and any repairs must be documented by the person who has performed them these documents must remain under the custody of the owner of th...

Page 32: ...www niceforyou com Nice SpA Oderzo TV Italy info niceforyou com IDV0689A00EN_30 06 2019...

Reviews: