elero GmbH
EN | 21
6. Check all required functions when the mains supply
is switched o
ff
.
4.8
Installation in installation box
• Use the installation box as a double box in
fl
ush-mounted, surface-mounted or cavity wall version
5 Operation
• Single input with interlocked push button / switch or
control unit with potential-free contact.
• Priority can be set for commands from the individual
or central input.
5.1
Individual and master control
ExitSafe is controlled via the individual
▲
, individual
▼
,
signal
▲
and signal
▼
inputs. These inputs must be
controlled using command initiators with potential-free
contacts. The drive connected to the ExitSafe system is
controlled on the basis of on these inputs.
The function of the inputs can be adjusted via the DIP
switches as described below.
5.2
Priority individual or master control
DIP switch 1 OFF
In this position, the
individual
▲
and
individual
▼
inputs have
priority over the signal
▲
and signal
▼
inputs.
DIP switch 1 ON
In this position, the
signal
▲
and
signal
▼
inputs have
priority over the individual
▲
and individual
▼
inputs if
operated simultaneously.