26
11.5 - Function (Continued)
Advance Settings:
The following settings are available for customizing the gate operator as required by the customer’s instal-
lation requirements:
Set Language (English, Spanish, Italian)
Set clock 12H/24H
Set LCD Contrast
Direction of the Motor (only selectable in learning mode)
Auto Close Opt. (ON - Gate only closes when at open limit, OFF - Gate auto-closes from any open po-
sition)
Exit Opt. (ON - Free Exit always opens gate, OFF - Free Exit doesn't open gate if stopped while open-
ing)
Set Anti-tailgate (Closes gate immediately after vehicle has cleared safety sensors)
Phototest (activates monitoring feature for BlueBus photoeyes)
Select inputs LOOP or PHOTO
Select UL/EDGE input type (NO, NC, Analog)
Select Master / Slave Motor1 or Motor2
Activate link for remote Master/Slave (Enables control of an additional gate operator board - Not Appli-
cable in this installation)
Power Fail Open (Opens gate automatically on batter backup power if main AC power input loss is de-
tected) (Not Applicable in this installation)
Motor 12V (Forces motor control voltage to +12VDC even if the supply voltage varies from +9.5VDC
up to +35VDC)
Set Virtual Encoder (Used for motors without built-in encoders)
Default:
This setting gives the installer/user the option of returning some or all
settings of the gate operator to the original factory settings:
• System settings
• Radio Channel settings
• Event settings
• Charger settings
ESC:
Exit the FUNCTION menu.