background image

 

29 

TABLE 3 

SYMPTOM(S) 

POSSIBLE SOLUTION 

Operator will not power 
On. 
Power LED is OFF 

 

Check terminal Lock wiring for loose or broken wires 

 

Check the fuse 

 

Check wiring polarity 

Gate opens a short dis-
tance, then stops and 
reverses 

 

Check the UL/Edge input on the gate controller 

 

Adjust Force Settings 

 

Check Motor 1 and Motor 2 encoder LEDs to verify the LEDs toggle when 
the gate is moving 

Gate opens but will not 
close 
 

 

Check the input LEDs. Any ON will hold the gate open and indicates a 
problem with a keying device 

 

Check the secondary safety devices. Any activated safety devices will 
hold the gate open and indicates a problem with the safety device 

 

Check the loop detectors. Any activated safety devices can hold the gate 
open and indicates a problem with the loop detector or ground loop 

Hard Shutdown (2 back 
to back obstructions) 
LED  blinking, Buzzer 
sounds for 5 minutes 

 

Clear any obstructions from the path of the gate. Press RESET to clear (or 
hard reset button) 

Gate opens by itself 

 

Check accessory inputs and clear them as necessary 

15 - APOLLO GATE OPENER TROUBLESHOOTING 

TABLE 2  

COMPLETE  BASIC 

 

Alarm 

Active the primary (inherent) reverse system by blocking the gate 
with a solid object. The gate should reverse momentarily then stop. 
Restart the gate and Lock again with a solid object. The gate should 
reverse momentarily, then stop, and go into hard shutdown with an 
alarm 

● 

● 

Battery  

Check the batteries for any leakage or loose connections. Batteries 
should be replaced every two years 

● 

 

Fire Dept 

Check emergency vehicle access device for proper operation 

● 

● 

Gate 

Inspect for damage 

● 

 

Reverse Sys-
tem 

Check that the gate reverses on contact with an object in both the 
opening and closing cycles 

● 

● 

Loop(s) 

Check vehicular reverse and shadow loops for proper operation 

● 

●  

Release 

Check manual release for proper operation 

● 

 

Complete 

Overall Check: Complete check of gate and gate operating system 

● 

 

Mounting Hard-
ware 

Check screws and nuts 

● 

 

14 - MAINTENANCE SCHEDULE - APOLLO GATE OPENER 

Summary of Contents for 1550ETL-1K

Page 1: ...1 Rev 1 0 INSTALLATION MANUAL Model 1550ETL 1K Single Swing Gate Operator Model 1650ETL 1K Dual Swing Gate Operator...

Page 2: ...Accessory Inputs 4 2 Communication buses 4 2 1 BLUEBUS ACCESSORIES 4 2 2 Programming the plug in receiver and remote controls 4 3 3 OVIEW REMOTE CONTROL 5 WIRING AND CONNECTIONS 16 6 OPTIONAL INPUTS...

Page 3: ...ccess Use the emergency release only when the gate is not moving A secondary entrapment device such as loop detectors edge switches and beam detectors are highly recommended and required to meet the U...

Page 4: ...d electrician will be required for proper electrical hook up The following table should be used as a guide for capacity of operation of operators only additional options may reduce the the daily usage...

Page 5: ...s there a suitable location for the operator 2 Can the solar panel if used be mounted in an unobstructed area facing south in the northern hemisphere 3 Will additional solar panel cable be required 4...

Page 6: ...TION Sign 2 each 4 each with 1650 Part 1116 Pivot Arm 2 with 1650 Part 10025215 Gate Bracket 2 with 1650 Part 1125 Hardware Kit 2with 1650 Part 201 5 Watt Solar Panel Bracket 2 required with 1650 Part...

Page 7: ...e closed position PUSH TO OPEN pushes the gate open actuator is retracted when gate is in the closed position For PUSH TO OPEN installations see page 11 If a 400 Upgrade Kit is to be used refer to the...

Page 8: ...1 3 Control Box Installation Mount the control box within 4 feet of the pivot arm Do not mount the control box where the person using the push button on side of the box can come in contact with the g...

Page 9: ...troller Install the 5 and 3 pin connector into the section labeled Motor 1 on the controller as shown in Figure 7 Install the 5 and 3 pin and connector into the section labeled Motor 2 for a dual leaf...

Page 10: ...ller until the gate is 50 open 8 Press FUNCTION LEARN SWING then press LIGHT AVERAGE OR HEAVY according to the size of the gate then press ENTER The gate will open partially then stop The gate will th...

Page 11: ...ING ACTUATOR TO PUSH OPEN Apollo 816 1K Red and Black motor power Note If gate moves in opposite direction from what is expected reverse the motor power lead wir ing Red to pin 3 Black to pin 1 Red bl...

Page 12: ...12 3 CIRCUIT BOARD LAYOUT Figure 15 CONTROL BOARD BUTTONS Figure 16 CIRCUIT BOARD LAYOUT...

Page 13: ...n the input is activated it stops the gate regardless of direction of travel momen tarily reverses it then stops Exit Input 30 Dry contact input for a vehicle exit sensor Opens gate from the closed po...

Page 14: ...contact input Normally Closed for a guard station stop switch Mo mentarily opening this input stops the opening gate at its current position While this input is activat ed all other inputs are disable...

Page 15: ...onds then re lease the button taking note of the button that was pressed 2 Press the same button on the programmed FloR A remote control three times 3 Press the same button in step 1 on the un program...

Page 16: ...PDA or Smartphone for wireless local national and international controller of the gate controller O VIEW Software Suite Provides desktop or Smartphone level control of the gate controller Oth er benef...

Page 17: ...EDGE input may be configured as a monitored ANALOG input or DIGITAL NC or NO input The EDGE sensor input is intended for ANSI UL 325 listed gate edge sensors to protect against entrapment and hazardo...

Page 18: ...on of fuses Ensure that they are of the correct type and amperage Insufficient clearance between exposed current carrying parts and ground or poor insulation of exposed termi nals All exposed connecti...

Page 19: ...19 Figure 25 LAYOUT FOR IN GROUND LOOPS Figure 26 LAYOUT FOR PHOTOCELLS 8 GENERAL LAYOUT AND SAFETY ACCESS...

Page 20: ...radio frequency RF signals to the gate operator for entrapment protection functions shall be located where the transmission of the signals are not ob structed or impeded by building structures natura...

Page 21: ...TED IN THE ABOVE REFERENCE SHOULD BE USED ONLY AFTER UNDERSTANDING THE MANUAL AND ITS RELATION TO THE PROGRAMMING SEQUENCES SHOWN ON THE FOLLOWING PAGES CARE SHOULD BE TAKEN WHENEVER CHANGES ARE IMPLE...

Page 22: ...f gate acceleration Standard Sets the limit of the gate acceleration in normal operation Settings from 1 to MAX with MAX being the highest rate of gate acceleration TO PREVENT DAMAGE TO THE GATE OR TH...

Page 23: ...ons STOP the gate and Auto closing HOLD TO OPEN Input must be maintain active for Opening HOLD TO CLOSE Input must be maintain active for Closing FIRE Reset Hard Shut Down and Open the Gate TIMER 1 St...

Page 24: ...imer 1 and Timer 2 Settings between 1 second and 9 hours in 1 second increments Events Up to 8 weekly events EV1 through EV8 can be programmed and stored Each event can be programmed to trigger at a s...

Page 25: ...end Event EV1 is now suspended and will not run until re enabled 4 Press UP or DOWN to toggle through the events EV1 EV8 and repeat steps 2 through 3 to suspend or enable other weekly events Charger A...

Page 26: ...eature for BlueBus photoeyes Select inputs LOOP or PHOTO Select UL EDGE input type NO NC Analog Select Master Slave Motor1 or Motor2 Activate link for remote Master Slave Enables control of an additio...

Page 27: ...sev eral seconds Maint Display the number of cycles before service is required Settings from 1000 to 50000 cycles in increments of 1000 cycles Motor Displays the Motor position voltage and current Mot...

Page 28: ...ELESS CONTROL A control implemented in means other than fixed physical interconnections such as radio waves or infrared beams between the control the associated devices and an opera tor to perform pre...

Page 29: ...obstructions from the path of the gate Press RESET to clear or hard reset button Gate opens by itself Check accessory inputs and clear them as necessary 15 APOLLO GATE OPENER TROUBLESHOOTING TABLE 2...

Page 30: ...1K SERIES LIMIT SCREW ADJUSTMENT as necessary until the Motor 1 LED turns RED 7 Press the Open button on the gate controller until the gate is 50 open 8 Press FUNCTION LEARN SWING then press LIGHT AVE...

Page 31: ...distance with minimal resistance applied Approximately 40 lbs on a swing gate at the end of the gate 8 The installer has instructed the customer in the proper use of the gate operator and reviewed all...

Page 32: ...fire flood or lightning The manufacturer will not be responsible for any labor charges incurred in the removal or replacement of defective parts In case of failure due to defective material or workman...