background image

Quick Start EDGE1

Rev03 18/08/2020

ROGER TECHNOLOGY

Via S. Botticelli 8 • 31021 Bonisiolo di Mogliano Veneto (TV) • ITALIA

P.IVA 01612340263 • Tel. +39 041.5937023 • Fax. +39 041.5937024

[email protected] • www.rogertechnology.com

A

EDGE1 - Motors connection

3x2,5 mm

2

 double insulated cable (max 10 m) - 3x4 mm

(max 30 m)

1

Photocell - Receiver

5x0,5 mm

2

 double insulated cable (max 20 m)

2

Photocell - Transmitter

3x0,5 mm

2

 double insulated cable (max 20 m)

3

Flashing lamp unit

2x1 mm

2

 double insulated cable (max 10 m)

4

Antenna

RG58 or KX6 50 Ohm cable for external use (max 10 m)

5

Selector / Keypad

3x0,5 mm

2

 cable (max 20 m)

1.  Typical installation

EDGE1 is the range of 36V DC digital controllers installed with the swing gates applications.

EN

2

2

3

4

1

A

A

5

1

Summary of Contents for EDGE1

Page 1: ...ulated cable max 10 m 3x4 mm2 max 30 m 1 Photocell Receiver 5x0 5 mm2 double insulated cable max 20 m 2 Photocell Transmitter 3x0 5 mm2 double insulated cable max 20 m 3 Flashing lamp unit 2x1 mm2 double insulated cable max 10 m 4 Antenna RG58 or KX6 50 Ohm cable for external use max 10 m 5 Selector Keypad 3x0 5 mm2 cable max 20 m 1 Typical installation EDGE1 is the range of 36V DC digital control...

Page 2: ... N 0 19 0 26 SEC2 SEC1 1 2 3 4 BATTERY CHARGER BATTERY TRANSFORMER Blu Blue Blu Blue L N Nero Black Nero Black Nero Black Nero Black Blu Blue Blu Blue MOTOR 1 MOTOR 2 FIFTHY 24 F4ES F4S Series 1 2 3 2 3 4 5 TX RX 1 CS STD 1 2 POWER SUPPLY 230 Vac 115 Vac BATTERIES 2 x 12V 4 5Ah 2 Electrical connections 3 Display functions and settings Accessories illustrated are indicative only PROG TEST Back Prog...

Page 3: ...se F3 and wait 5 seconds Reconnect to mains power or refit the fuse Press and hold PROG until the message and appear on the display Repeat acquisition procedure 4 Before starting d Move the gate into the completely CLOSE position e Press TEST button Possible alarms and safety device messages SEE ACQUISITION PROCEDURE PROG TEST PROG TEST PROG TEST a Select the automation system model installed with...

Page 4: ...ment MOTOR2 Deceleration MOTOR 1 during CLOSING Deceleration MOTOR 2 during CLOSING Opening speed Opening speed Closing speed Closing speed Start acceleration MOTOR 2 during opening MOTOR 1 MOTOR 2 6 Setting basic parameters 5 Acquisition procedure 1 Press and hold PROG for 4 seconds 2 APP appears on the display 3 Press PROG 4 AUTO appears on the display 5 MOTOR 1 starts opening at low speed 6 Aft...

Page 5: ... s 3 Hold button A only on the NEW transmitter you want to store 4 The LED flashes 3 s 5 Hold the previously stored transmitter as close as possible to the NEW transmitter 6 Press button A on the OLD transmitter 7 The LED lights for 1 s to confirm that the copy procedure was successful 9 Photocells grounding connection Grounding connection negative terminal COM photocells series F4ES F4S or other ...

Reviews: