10
NIBE PB 10
Installation
Commissioning and adjusting
Adjustment template
Adjusting the burner
Q
Check the pellet level. During operation the holes on
the grate must be covered with pellets.
Q
Pellet supply changed using P2 on the circuit board
(increased clockwise and reduced anti-clockwise). Also
check the air damper and flue gas temperature.
Q
In the event of the pellet level being too high, increase
the air supply by opening the damper on the fan or
reducing the pellet supply (P2).
Q
Check the flue gas temperature (normally between
170–240 ºC). If the temperature is too high reduce the
pellet supply with P2.
Q
If the temperature is too low, increase the air supply
with the air damper.
Q
In the event of low fuel level in the burner. Check the
flue gas temperature as above, reduce the air supply or
increase the pellet supply (P2).
Make adjustments to the burner using a
flue gas analysis instrument for optimal
combustion.
Note!
P1
P2
P3
P4
P5
Supply time
Firing supply
Extinguishing
time
Overrun time
Photocell
0 Flashes
30 seconds
1.5 seconds
30 seconds
45 seconds
0 sensitivity
1 Flashes
45 seconds
1.7 seconds
60 seconds
90 seconds
1 sensitivity
2 Flashes
60 seconds
1.8 seconds
90 seconds
135 seconds
2 sensitivity
3 Flashes
75 seconds
2.2 seconds
120 seconds
180 seconds
3 sensitivity
4 Flashes
90 seconds
2.8 seconds
150 seconds
225 seconds
4 sensitivity
5 Flashes
105 seconds
3.7 seconds
180 seconds
270 seconds
5 sensitivity
6 flashes
120 seconds
4.8 seconds
210 seconds
315 seconds
6 sensitivity
7 Flashes
135 seconds
6.2 seconds
240 seconds
360 seconds
7 sensitivity
8 Flashes
150 seconds
7.5 Seconds
270 seconds
405 seconds
8 sensitivity
9 Flashes
165 seconds
8.2 seconds
300 seconds
450 seconds
9 sensitivity
Factory setting
75 seconds
3.7 seconds
150 seconds
270 seconds
5 sensitivity
Default setting is shaded
When changing from 8 mm to 6 mm pel-
lets, the burner must be adjusted.
Note!
Summary of Contents for PB 10
Page 1: ...MOS GB 0951 2 PB 10 511891 INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE PB 10 LEK...
Page 2: ......
Page 5: ...3 NIBE PB 10 User guide General System diagram M...
Page 18: ...16 NIBE PB 10 Installation Electrical connection of PB 10 to PELLUX...
Page 19: ...17 NIBE PB 10 Installation Electrical connection of PB 10 to PELLUX...
Page 28: ...26 NIBE PB 10...
Page 29: ...27 NIBE PB 10...
Page 30: ...28 NIBE PB 10...
Page 31: ......