9
NIBE PB 10
Installation
Adjusting control electronics
Potentiometers P1-P5 are adjustment potentiometers for
trimming the functions of the burner. The potentiometers
are designated with the relevant abbreviations (P1-P5).
The circuit board has 3 LEDs (LD1,LD2,LD3).
Functions P1-P5
Pot
Function
Seconds
Comments
P1
Feed time igni-
tion dose (start
fuel)
30 – 165
Pellets must just
cover the upper
ignition hole on the
ignition plate.
P2
Firing supply
1,5 – 8,2
Pellets fed every 15
seconds.
P3
Extinguishing
time
30 – 300
The time the fan
runs after the photo-
cell has lost light in
the burner.
P4
Overrun time (at
25% supply)
45 – 450
Time between igni-
tion and normal
operation.
P5
The sensitivity of
the photocell
0 – 9
9= max fire/light
intensity, 0= min fire/
light intensity.
Reading off potentiometers
To see how a potentiometer is set, the relevant potentiom-
eter flashes first on LD3 (green) and then the value which
is set on LD2 (yellow) flashes. This occurs continuously,
1,2,3,4,5,1,2,3…… regardless of whether the burner is in
operation or not.
Example: If the photocell loses light for more than 3 sec-
onds the fan runs for a further 6 seconds, the burner then
carries out normal extinguishing according to the set value
on P4.
Do not adjust the burner during operation
- High voltage circuit-board!
WARNING!
!
LD1
P3
P5
P4
P2
P1
LD2
LD3
Summary of Contents for PB 10
Page 1: ...MOS GB 0951 2 PB 10 511891 INSTALLATION AND MAINTENANCE INSTRUCTIONS NIBE PB 10 LEK...
Page 2: ......
Page 5: ...3 NIBE PB 10 User guide General System diagram M...
Page 18: ...16 NIBE PB 10 Installation Electrical connection of PB 10 to PELLUX...
Page 19: ...17 NIBE PB 10 Installation Electrical connection of PB 10 to PELLUX...
Page 28: ...26 NIBE PB 10...
Page 29: ...27 NIBE PB 10...
Page 30: ...28 NIBE PB 10...
Page 31: ......