background image

GETTING STARTED GUIDE

NI PXIe-4138/4139

PXIe, ±60 V, ±3 A (DC)/±10 A (Pulsed) Precision System PXI Source
Measure Unit

This document explains how to install, configure, and test the PXIe-4138/4139. The
PXIe-4138/4139 ships with NI-DCPower driver software, which you can use to program the
module.

Note

 

Before you begin, install and configure your chassis and controller.

Note

 

In this document, the PXIe-4139 (40W) and PXIe-4139 (20W) are referred to

inclusively as the PXIe-4139. The information in this document applies to all
versions of the PXIe-4139 unless otherwise specified. To determine which version of
the module you have, locate the device name in one of the following places:

In MAX

—The PXIe-4139 (40W) shows 

NI PXIe-4139 (40W)

, and the

PXIe-4139 (20W) shows as 

NI PXIe-4139

.

Device front panel

—The PXIe-4139 (40W) shows 

PXIe-4139 40W System

SMU

, and the PXIe-4139 (20W) shows 

NI PXIe-4139 Precision System SMU

on the front panel.

Contents

Verifying the System Requirements..........................................................................................2
Unpacking the Kit..................................................................................................................... 2
Kit Contents.............................................................................................................................. 2
Other Equipment....................................................................................................................... 3
Preparing the Environment....................................................................................................... 3
Installing the Software.............................................................................................................. 3
Installing the PXIe-4138/4139.................................................................................................. 4
PXIe-4138 Pinout .....................................................................................................................6
PXIe-4139 Pinout .....................................................................................................................8
Configuring the PXIe-4138/4139 in MAX............................................................................... 9
Self-Calibrating the PXIe-4138/4139..................................................................................... 10
Programming the PXIe-4138/4139......................................................................................... 11
Troubleshooting...................................................................................................................... 13

What Should I Do if the PXIe-4138/4139 Doesn't Appear in MAX?............................ 13
Why Is the ACCESS LED Off When the Chassis Is On?...............................................14
What Should I Do if the PXIe-4138/4139 Fails the Self-Test?.......................................14

Where To Go Next.................................................................................................................. 15
NI Services..............................................................................................................................15

Summary of Contents for PXIe-4138

Page 1: ...one of the following places In MAX The PXIe 4139 40W shows NI PXIe 4139 40W and the PXIe 4139 20W shows as NI PXIe 4139 Device front panel The PXIe 4139 40W shows PXIe 4139 40W System SMU and the PXIe...

Page 2: ...atic package to a metal part of the computer chassis 2 Remove the module from the package and inspect it for loose components or other signs of damage Notice Never touch the exposed pins of connectors...

Page 3: ...t number 199198 01 NI screwdriver NI part number 781015 01 Visit ni com for more information about these additional items Preparing the Environment Ensure that the environment you are using the PXIe 4...

Page 4: ...installing the PXIe 4138 4139 The AC power cord grounds the chassis and protects it from electrical damage while you install the PXIe 4138 4139 2 Power off the chassis 3 Inspect the slot pins on the c...

Page 5: ...Note Tightening the top and bottom mounting screws increases mechanical stability and also electrically connects the front panel to the chassis which can improve the signal quality and electromagnetic...

Page 6: ...O SENSE LO SENSE HI HI GUARD GUARD ACCESS ACTIVE OUTPUT OUTPUT CAT I C D E F G H I J A B K Table 1 Signal Descriptions Item Description A Access Status LED B Active Status LED C Output LO D Sense LO E...

Page 7: ...ff Not Powered Green Powered Amber Device is being accessed Table 3 LED Active Status Indicator Status Indicator Output Channel State Off Channel not operating in a programmed state Green Channel oper...

Page 8: ...CTIVE OUTPUT OUTPUT CAT I C D E F G H I J K A B PXIe 4139 40W System SMU 60 V 3 A 10 A Pulse MAX 150 V MAX to LO SENSE LO SENSE HI HI GUARD GUARD ACCESS ACTIVE OUTPUT OUTPUT CAT I K A B Table 4 Signal...

Page 9: ...in a programmed state Red Channel disabled because of error such as an overcurrent condition Configuring the PXIe 4138 4139 in MAX Use Measurement Automation Explorer MAX to configure your NI hardwar...

Page 10: ...he first time you install the PXIe 4138 4139 1 Install the PXIe 4138 4139 and let it warm up for 30 minutes Note Warm up begins when the PXI Express chassis has been powered on and the operating syste...

Page 11: ...generate signals interactively using InstrumentStudio or you can use the NI DCPower instrument driver to program your device in the supported ADE of your choice NI PXIe 4138 4139 Getting Started Guid...

Page 12: ...tudio year This launches InstrumentStudio and runs a soft front panel populated with devices detected on your system From Measurement Automation Explorer MAX select a device and then click Test Panels...

Page 13: ...Files IVI Foundation IVI Refer to the Creating an Application with NI DCPower in Microsoft Visual C and C topic of the NI DC Power Supplies and SMUs Help installed with the NI DCPower driver software...

Page 14: ...ernal signals only while the PXIe 4138 4139 is powered on Applying external signals while the module is powered off may cause damage 1 Disconnect any signals from the module front panels 2 Power off t...

Page 15: ...m support Power Supplies Solutions ni com powersupplies Services ni com services NI Community ni com community NI PXIe 4138 Getting Started with LabWindows CVI Getting Started with LabVIEW NI DCPower...

Page 16: ...and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to...

Reviews: