13 Calibration setting up the Sea Data instrument
To get the most out of your Nexus instrument, it is important to
carefully calibrate the instrument. The calibration values are
stored in a memory and will keep the values even if the instrument
is un powered for more than 1o years.
To access calibration mode, press and hold
SET
more than 2
seconds.
To select a calibration code, press
MINUS
,
PLUS
as required.
To return to normal mode, press
PAGE
followed by
SET
when the
text return (RET) is displayed.
To change a calibration value, press
SET
.
To select calibration value, press
MINUS
,
PLUS
and
PAGE
as
required.
To lock the selected value, press
SET
13.1 Calibration of speed C10
13.1.1
Return C10 (RET)
To return to normal mode, press
SET
.
13.1.2
Unit for Speed, C11 (Unit KTS)
Unit for speed. Knots (KTS), km/h (K/h) or miles/h (m/h).
Note, this is a local setting and has to be done on both Sea Data
and the Wind instrument
13.1.3
Calibration of Speed, C12 (1.25 CAL)
This is a system setting and you only need to enter the value on
one of the instruments.
Calibration value for speed and distance (0.00 - 1.99).
Drive the boat a measured distance at normal speed.
Compare the distance with the trip counter.
Calculate the value with the following formula:
True distance from the sea chart :
T
Log trip counter distance:
L
The current calibration value:
C
New calibration value.
N
Summary of Contents for NX Start Pack 2
Page 1: ...Installation and Operation Manual NX Start Pack 4 English...
Page 2: ...Start pack 4 English 1...
Page 3: ...English Start pack 4 2 Edition April 2007...
Page 7: ...English Start pack 4 6 Instrument Installation and Operation Manual NX Sea Data English...
Page 15: ...English Start pack 4 14 2 5 Electrical Installation 3A Fuse...
Page 30: ...Start pack 4 English 29 WIND...
Page 40: ...Start pack 4 English 39...
Page 45: ...English Start pack 4 44 17 Waranty...
Page 46: ...Start pack 4 English 45...
Page 47: ...English Start pack 4 46...