2. Press the PLUS button until the text C15 is showed
3. Note the value for C15.
4. Press SET (short) and enter the value 99.9 using MINUS, PLUS and PAGE.
5. Press
SET.
6. The WSI-boxen has now released the pairing and you can now enter the value you
noted under point 3 again
7. Press PAGE followed by SET to exit the setting mode
B From a NX Wind instrument
1. Press and hold the SET button for two seconds
2. Press the PAGE button until the text C50 is showed
3. Press the PLUS button until the text C53 is showed
4. Note the value for C53 (normally 1.70).
5. Press SET (short) and enter the value 1.99 using MINUS, PLUS and PAGE.
6. Press
SET.
7. The WSI-boxen has now released the pairing and you can now enter the value
you noted under point 4 again
8. Press PAGE followed by SET to exit the setting mode
Release the pairing of the wind transducer
To release the Wind transducer and re-initializing it, press and hold the INIT button (see
picture on previous page) for 5s. Use the supplied initialization pin.