English
Start pack 4
18
8 First
start
8.1
Initialising the instrument
You will be asked to press
SET
(PrESkey)
on the instruments the very first time after
installation. This will give the instrument a
logical ID number that belongs to your
specific Nexus Network.
Press
SET
, on each installed instrument, one
at the time.
Always wait for the text ‘Init OK’
to be displayed, before you
press SET on the next
instrument!
The first unit ID number is 16, then 17 and so
on in the order which you press
SET.
The example shows that the Sea Data
instrument version number is 1.0 and that
the instrument was given the logical ID
number 16.. The Wind instrument has
version no. 1.00 and ID number 17
The bottom row in the Sea Data shows the
software version (4.8) and ID number (0) of
the network master (WSI-box or Server).
When the NX WSI-box is network master,
the ID number is 2
When the NX2 Server is network master, the ID
number is 0
Sea Data
Wind