background image

 

Start pack 4

 English 

 

41 

15.2.2 

Fault - action 

1. Speed and distance functions: No reading ( --- )

   

For more information, see manual for WSI-box or NX2 Server. 
 

Irregular values: 

Check the speed damping (SEA), (see 13.1.4). 

 

2. Wind: No reading ( --- )

 

For more information, see manual for WSI box or NX2 Server. 

 
 

15.2.3 Error 

messages 

 

The following error messages can appear on the display:

 

 

ERROR 2

 

Nexus Network is missing, check colour coded 

connections 

ERROR 3

 

No data received within a given time. 

ERROR 10

 

Range error caused by bad format e.g. 400°. 

 
If other error messages than the above appears on the Sea Data 
instrument, contact your Nexus dealer. 

Summary of Contents for NX Start Pack 2

Page 1: ...Installation and Operation Manual NX Start Pack 4 English...

Page 2: ...Start pack 4 English 1...

Page 3: ...English Start pack 4 2 Edition April 2007...

Page 4: ...ons of the Sea Data 19 8 3 Instrument backlight 20 9 Function overview of the Sea Data 20 10 SPEED functions 21 SPEED main function 21 SPEED sub functions 21 TRIP LOG TRP 21 TOTAL LOG LOG 21 START TIM...

Page 5: ...19 Unit m s 34 13 1 11 Adjustment of Wind Angle C20 000 ADJ 34 13 1 12 Damping of Wind Readings C21 SEA LOW 34 13 1 13 Key beep setting C22 OFF KEY 34 14 Calibration and setup of the Wind instrument 3...

Page 6: ...m 0 3 inch 11 1 3m red power cable 12 1 3m black power cable 13 2 Through hull fitting with nut 14 2 Locking device 14 1 Log transducer TH43 15 1 Depth transducer TH43 16 2 Dummy plug 17 8 O ring 18 3...

Page 7: ...English Start pack 4 6 Instrument Installation and Operation Manual NX Sea Data English...

Page 8: ...at the Server so it can be disconnected for inspection without having to disconnect all attached cables Do not place sealant behind the display The instrument gasket eliminates the need for sealant D...

Page 9: ...s from the back Note The two nuts must just be tighten by hand only Run the Nexus Network cable from the WSI box to the instrument If you want to cut the Nexus Network cable to length disconnect 4 pol...

Page 10: ...ansducer 2 3 1IMPORTANT Installation information BEFORE placing the wind transducer on the mast a pairing procedure must be done 2 3 2Location The transducer should be mounted on a horizontal surface...

Page 11: ...g holes using the bracket as an template 3 Mount the bracket with the three supplied screws 5 Tighten the lock nut by hand only do not use any tool 2 Drill the three mounting holes using a 3 2mm drill...

Page 12: ...rom the speed transducer If the transducers are mounted on the center line of the boat the depth transducer should be mounted about 40cm in front of the speed transducer It is important that the trans...

Page 13: ...aims at the bow rather than directly parallel to the centreline This will help balanced the passing waterflow measurement from one tack to another Avoid placing the transducer near the edge of sharp...

Page 14: ...cone grease to the exterior of the dummy plug 5 Install the dummy plug in the through hull fitting Use a slow twisting motion and be sure that is properly seated into the fitting 6 With the dummy plug...

Page 15: ...English Start pack 4 14 2 5 Electrical Installation 3A Fuse...

Page 16: ...00kHz transducers are available for all types of Nexus through hull fittings The Nexus network cable of the NX system may be connected at any location in the existing Nexus system That is normally at...

Page 17: ...ibed above n r den ter skall monteras Se procedur enligt ovan 6 Maintenance If you have been using the Wireless wind for several seasons you may need to change the rechargeable cells Use Nexus origina...

Page 18: ...for two seconds 2 Press the PAGE button until the text C50 is showed 3 Press the PLUS button until the text C53 is showed 4 Note the value for C53 normally 1 70 5 Press SET short and enter the value...

Page 19: ...yed before you press SET on the next instrument The first unit ID number is 16 then 17 and so on in the order which you press SET The example shows that the Sea Data instrument version number is 1 0 a...

Page 20: ...log cancel alarms or reset the timer MINUS Move to the next sub function In edit mode Decreases the shown value PLUS Move to the previous sub function In edit mode Increase the shown value SET Set or...

Page 21: ...The selected page is indicated by the LCD mark at top of the display Each page has 2 types of functions that can be displayed together 1 Main function displayed at the top of the display in 30 mm high...

Page 22: ...LEAR TOTAL LOG LOG Distance from 0 to 19999 NM The total log can not be reset START TIMER STA Count down timer can be set between 59 and 1 minute To start the timer from minus 10 minutes 10 STA press...

Page 23: ...h reading can be set to show distance from the water surface or from the keel Unit in meters m feet FT or fathoms FA The text alternates between the selected unit and DPT BATTERY BAT The Battery volta...

Page 24: ...the pre set value ANCHOR ALARM Aaudible and visual alarm is activated if the actual depth becomes less or deeper than the pre set values Set shallow SHA alarm to actual depth minus 1 5 m 5 FT then se...

Page 25: ...cted value By this last press on SET you have turned on the selected alarm function which is indicated by the minute sign above the last depth digit in the sub function 11 3 Set and turn on anchor ala...

Page 26: ...o be turned off on To turn the alarm off on press CLEAR The minute sign disappears appears When a triggered alarm has been silenced it will only be triggered again if the selected depth value differs...

Page 27: ...age to SPEED page Select DEPH page and find the sub function TWS Press PAGE and SET together All digits flash To move and copy to SPEED page press PAGE To lock the function press SET Each time the SPE...

Page 28: ...ious digit PLUS A press on PLUS moves to the previous sub function In edit mode it increases to the next digit SET A press on SET unlocks a digit to access edit mode When unlocked the digits are activ...

Page 29: ...arent Wind Angle TWA True Wind Angle requires a log transducer To change between these functions see C12 14 1 2 12 7 Analogue function Wind scale is showing 180 wind angle 5 degree segment The text AP...

Page 30: ...Start pack 4 English 29 WIND...

Page 31: ...F BeauFort 12 8 3 Velocity Made Good VMG The text VMG Velocity Made Good is displayed with the actual boat speed towards or against the Wind The water speed information from the log transducer is need...

Page 32: ...t Reference for Direction See 14 1 7 Text TWD is displayed shortly then is the abbreviation for Wind directions displayed SSW NO WNW etc together with the numerical direction below The graphic directi...

Page 33: ...value press MINUS PLUS and PAGE as required To lock the selected value press SET 13 1 Calibration of speed C10 13 1 1 Return C10 RET To return to normal mode press SET 13 1 2 Unit for Speed C11 Unit K...

Page 34: ...5 Unit for Depth readings C14 Unit m Unit for depth Metre m feet Ft or fathoms FA Note this is a local setting and has to be done on both Sea Data and the Wind instrument 13 1 6 Adjust Depth readings...

Page 35: ...choose any horizontal mounting angle Example 1 If the wind angle is 4 from Starboard when you sail drive the boat straight into the wind Set the calibration channel C54 to 356 Example 2 If the wind a...

Page 36: ...ue press SET To select calibration value press MINUS PLUS and PAGE as required To lock the selected value press SET 14 1 User settings C10 To return to normal PAGE press SET when the text rET is displ...

Page 37: ...1 6 Reference for Speed water or GPS C16 Select speed reference Log transducer Nexus or SOG BSP Log signals direct in to the Wind instrument NEX Boat speed information comes via the Nexus Network Ser...

Page 38: ...values are simulated in this PAGE It is convenient to learn the functions of the instrument by using this PAGE Every 7th second the text DEM will appear to alert you that the demo PAGE is selected 14...

Page 39: ...ontal angle Example If the Wind angle is 4 when you sail drive the boat straight into the Wind set the calibration value in C54 to 356 14 2 4 Calibration for the Wind transducer C55 C62 Note this sett...

Page 40: ...Start pack 4 English 39...

Page 41: ...ease check the following points and make a list of All connected instrument and trancducers including their software version numbers Server software version number Nexus Network data bus ID numbers fo...

Page 42: ...No reading For more information see manual for WSI box or NX2 Server 15 2 3 Error messages The following error messages can appear on the display ERROR 2 Nexus Network is missing check colour coded c...

Page 43: ...Technical specifications Wind Instrument Dimensions 113 x 113 x23 mm 4 3x4 3 inch Instrument cable 8 m 26 ft Power supply 12V DC 10 16V The instruments are polarity protected Power consumption at 12V...

Page 44: ...Start pack 4 English 43 CE approval The products conforms to the EMC requirements for immunity and emission according to EN 50 08 1...

Page 45: ...English Start pack 4 44 17 Waranty...

Page 46: ...Start pack 4 English 45...

Page 47: ...English Start pack 4 46...

Page 48: ...Start pack 4 English 47 22880 1 Edition 3 Copyright Nexus Marine AB Kuskv gen 4 191 62 Sollentuna Sweden Tel 46 0 8 506 939 00 Fax 46 0 8 506 939 01 www nexusmarine se...