6.4 - SETTING TYPE OF INPUTS VIA WIRE
Default: Button function
This procedure lets you choose the type of wired devices to command load (connected on terminals 9 and 10).
The devices can be set as buttons or switches.
PROCEDURE
STEP 1
With a paper clip makes a long press of the “hidden” button.
The LED is cyclically yellow and cyane.
Release the key when the led is cyane.
ACTION:
Long press of hidden button
LED:
Turns on yellow/cyane
STEP 2
Press the button on the receiver for a short time and count
the number of Flashes emitted by the LED:
3 Flashes = control with buttons
6 Flashes = control with switches
ACTION:
Short press of button 2
LED:
Flashes
STEP 3
To change the setting, repeat the procedure from point 1;
the control unit will alternate between 3 and 6 Flashes
18