NEXPEED NR304G-4W User’s Manual
NexComm Systems, Inc. 85 PAGE
Example1. Bridging Configuration with 4-wire
This example explains how to connect two NR304G-4W routers using 4 wires, with the bridging
configuration method. To bind s0 and s1 ports, configure a MXL interface.
A company has received a C class , 256 IP addresses from 203.247.170.0 to 203.247.170.255 and
will configure local area network(LAN) with this addresses. But a company has two offices and it
is a far cry from one office to the other office about 2km.
[Network Diagram]
The SHDSL data rate is 4640kbps, refer to the following IP address:
1>
The gateway(router) address and subnet mask : 203.247.170.254/255.255.255.0
2>
The NR304GH-4W #1’s LAN IP address and subnet mask : 203.247.170.253/255.255.255.0
3>
The NR304GH-4W #2’s LAN IP address and subnet mask : 203.247.170.252/255.255.255.0
4>
Use IP unnumbered on MXL(SHDSL) interface.
Note
:
Configure the gateway of the PC connected with each NR304GH-4W as
“203.247.170.254” which is that of the whole network.