193
SLIDEOUTS
How to Manually Lift a Hydraulic Flat Floor Slideout
This article provides instructions for manually lifting a hydraulic flat floor slideout.
1. Determine which synchronizing cylinder controls the
room. Manually open the valve release cams for the
extend and retract solenoid valves by moving the
cams to the “valve opened” position as shown.
If the pump manifold is equipped with an auxiliary hand
pump, you may be able to retract the room by opening
only the room retract valve (as labeled by the wiring
harness) and operating the hand pump, refer to the
“Auxiliary Hand Pump Operation” page (in your HWH
Operator’s Manual) for instructions on the use of the hand
pump and valves equipped with a release cam. If the
room cannot be retracted with the hand pump, it will be
necessary to use the lift bolts and room retract screws.
2. Locate the lift cylinder covers, like the examples
shown. Some coaches may have an additional rubber
cover installed over the ABS cover to protect the lift
from the outside elements.
3. Do not remove the screws on the flat side of the
cover. Instead, remove the screws on the side of
the cover, allowing the entire cover to be removed.
Depending on the location, some covers may be
sealed with foam or another sealant.
CAUTION
!
Contact Newmar Customer Service (1-800-731-8300)
prior to manually lifting or retracting your Hydraulic
Flat Floor Slideout.
These brief operation instructions are for quick
reference only and should not take the place of
the complete manual(s) provided by this product’s
manufacturer. Refer to the corresponding links and
files in Newgle for more details about your product.
IMPORTANT
!
Release cam might be rotated to any direction on
the valve. Make sure to move the release cams in the
correct direction. Incorrect movement of the cams
can damage the valves.
IMPORTANT
!
Manual room lift procedures must be done before
manual room retraction procedures.