Enter Setup
】
Set Length Range for Codabar
The scanner can be configured to only decode Codabar barcodes with lengths that fall between (inclusive) the minimum
and maximum lengths. To accomplish it, you need to set the minimum and maximum lengths.
【
Set the Minimum Length (Default: 1)
】
【
Set the Maximum Length (Default: 127)
】
If minimum length is set to be greater than maximum length, the scanner only decodes
Codabar barcodes with either the minimum or maximum length. If minimum length is
same as maximum length, only Codabar barcodes with that length are to be decoded.
Set the scanner to decode Codabar barcodes containing between 8 and 12
characters:
1. Scan the
Enter Setup
barcode.
2. Scan the
Set the Minimum Length
barcode.
3. Scan the numeric barcode “8”. (See the
Digit Barcodes
in
Appendix
)
4. Scan the
Save
barcode. (See the
Save/Cancel Barcodes
in
Appendix
)
5. Scan the
Set the Maximum Length
barcode.
6. Scan the numeric barcode “1”.
7. Scan the numeric barcode “2”.
8. Scan the
Save
barcode.
9. Scan the
Exit Setup
barcode.
**
【