nlscan.com
Page 87
Symbols
Code Programming ON
Code Programming OFF
Tools
UCC/EAN-128
Select Message Length
It is used to program the valid reading length of UCC/EAN-128. The engine
will not send barcode message to the Host, if the decoded data length does not
match the valid length.
UCC/EAN-128 Message Length is de
fi
ned by
“
Min. Message Length
”
and
“
Max. Message Length .
”
Min Message Length (default: 1)
【
Pro CMD
:
0412030
】
Max Message Length (default: 48)
【
Pro CMD
:
0412040
】
1D bar code Message Length should not exceed 127 bytes. If Max Message Length is
less than Min Message Length, it means the engine will only support barcodes of the two
lengths. If Max Message Length is equal to Min Message Length, the engine will only sup-
port barcodes of the length.
To set Min Message Length of UCC/EAN-128 to 8 bytes and Max Message Length to 12
bytes, read these programming codes:
1.
“
Code Programming ON
”
2.
“
Select Min Message Length
”
3. Digit Code
“
8
”
, see Digit Code
4.
“
Save Programming
”
, see Digit Code
5.
“
Select Max Message Length
”
6. Digit Code
“
1
”
7. Digit Code
“
2
”
8.
“
Save Programming
”
9.
“