nlscan.com
Page 101
Symbols
Code Programming ON
Code Programming OFF
Tools
Plessey
Min Message Length (default: 4)
【
Pro CMD
:
0419030
】
Max Message Length (default:48)
【
Pro CMD
:
0419040
】
Select Message Length
1D bar code Message Length should not exceed 127 bytes. If Max Message Length is
less than Min Message Length, it means the engine will only support barcodes of the two
lengths. If Max Message Length is equal to Min Message Length, the engine will only sup-
port barcodes of the length.
It is used to program the valid reading length of Plessey. The engine will not
send barcode message to the Host, if the decoded data length does not match
the valid length.
Plessey Message Length is de
fi
ned by
“
Min. Message Length
”
and
“
Max.
Message Length .
”
To set Min Message Length of Plessey to 8 bytes and Max Message Length to 12 bytes,
read these programming codes:
1.
“
Code Programming ON
”
2.
“
Select Min Message Length
”
3. Digit Code
“
8
”
, see Digit Code
4.
“
Save Programming
”
, see Digit Code
5.
“
Select Max Message Length
”
6. Digit Code
“
1
”
7. Digit Code
“
2
”
8.
“
Save Programming
”
9.
“
Code Programming OFF
”