164
k. Program the Length Range (Maximum/Minimum Lengths) for a Symbology
Note:
If minimum length is set to be greater than maximum length, the scanner only decodes barcodes
with either the minimum or maximum length. If you only want to read barcodes with a specific length, set
both minimum and maximum lengths to be that desired length.
Example: Set the scanner to decode Code 128 barcodes containing between 8 and 12 characters
1. Scan the
Enter Setup
barcode.
2. Scan the
Set the Minimum Length
barcode from the
“Set Length Range for Code 128” section in
Chapter 7.
3. Scan the numeric barcode
“8”.
4. Scan the
Save
barcode.
5. Scan the
Set the Maximum Length
barcode from the
“Set Length Range for Code 128” section in
Chapter 7.
6. Scan the numeric barcodes
“1” and “2”.
7. Scan the
Save
barcode.
8. Scan the
Exit Setup
barcode. (If you still need to program other parameter/feature, skip this step.)
Summary of Contents for NLS-FM3051-2X
Page 1: ...NLS FM305X 2X Fixed Mount Barcode Scanner User Guide...
Page 4: ......
Page 13: ...Appendix 9 Code Pages List 172 Appendix 10 Symbology ID Number 173...
Page 14: ......
Page 17: ...Enter Setup 3 Exit Setup Dimensions unit mm FM3056 2X Scanner...
Page 18: ...Enter Setup Exit Setup 4 FM3051 2X Scanner...
Page 19: ...Enter Setup 5 Exit Setup IR Triggering Range...
Page 20: ...Enter Setup Exit Setup 6 Optics Horizontal...
Page 21: ...Enter Setup 7 Exit Setup Vertical...
Page 31: ...Enter Setup 17 Exit Setup Stop Bits 1 Stop Bit 2 Stop Bits...
Page 56: ...Enter Setup Exit Setup 42 Beep Type Type 1 Type 3 Type 2 Beep Volume Loud Low Medium...
Page 181: ...167 Appendix 6 Digit Barcodes 0 9 0 5 1 6 2 7 3 8 4 9...
Page 182: ...168 A F A B C D E F...