nlscan.com
Page 102
Symbols
Tools
Code Programming ON
Code Programming OFF
Codabar
Select Message Length
Codabar Message Length is de
fi
ned by
“
Min. Message Length
”
and
“
Max. Message Length
“
.It is used to program the valid reading length of
Codabar. The engine will send an error beep, if the decoded data length does
not match the valid length.
1D bar code Message Length should not exceed 255 bytes. If Max Message Length is less
than Min Message Length, it means the engine will only support barcodes of the two lengths.
If Max Message Length is equal to Min Message Length, the engine will only support
barcodes of the length.
To set Min Message Length of Codabar to 8 bytes, and Max Message Length to 12 bytes,
read these programming codes:
1.
“
Code Programming ON
”
2.
“
Select Min Message Length
”
3. Digit Code
“
8
”
, see Digit Code (Appendix Pxxx)
4.
“
Save Programming
”
, see Digit Code (Appendix Pxxx)
5.
“
Select Max Message Length
”
6. Digit Code
“
1
”
7. Digit Code
“
2
”
8.
“
Save Programming
”
9.
“
Code Programming OFF
”
Min Message Length
【
Pro CMD
:
99912514
】
Max Message Length
【
Pro CMD
:
99912515
】