The door-unlocking combination 3 is set as (09 09 09 09 09), indicating that there are 5
people in this combination; all of which are from AC group 9.
The door-unlocking combination 4 is set as (03 05 08 00 00), indicating that the
unlocking combination 4 consists of three people. The first person is from AC group 3,
the second person is from AC group 5, and the third person is from AC group 8.
Delete a door-unlocking combination
Set all group number as 0 if you want to delete door-unlocking combinations.
9.5-
ANTI-PASSBACK SETUP
It is possible that users may be followed by some persons to enter
the door without verification, resulting in security problem. So, to
avoid this situation, Anti-Passback option is developed. Once it is
enabled, the check-in record must match with check- out record so
as to open the door.
This function requires two devices to work together: one is installed inside the door
(master device), the other one is installed outside the door (slave device). The two
devices communicate via Wiegand signal. The Wiegand format and Output type (User ID
/ Badge Number) adopted by the master device and slave device must be consistent.
Click Anti-passback Setup on the Access Control interface.
Items
Descriptions
Anti-passback direction
No Anti-passback
: Anti-passback function is disabled, which means
successful verification through either master device or slave device can
unlock the door. Attendance state is not saved.