Auxiliary input
configuration
Set the door unlock time period and auxiliary output type of the auxiliary
terminal device. Auxiliary output types include None, Trigger door open,
Trigger Alarm, Trigger door open and Alarm.
Speaker Alarm
To transmit a sound alarm or disassembly alarm from the local. When the
door is closed or the verification is successful, the system will cancel the
alarm from the local.
Reset Access Setting
The restored access control parameters include door lock delay, door
sensor delay, door sensor type, verification mode, door available time
period, normal open time period, master device, and alarm. However,
erased access control data in Data Mgt. is excluded.
9.2-
TIME SCHEDULE
The entire system can define up to 50 time rules. Each time rule represents ten time
zones, i.e. one week and 3 holidays, and each time zone is a valid time period within 24
hours per day. You may set a maximum of 3 time periods for every time zone. The
relationship among these time periods is “or”. When the verification time falls in any one
of these time periods, the verification is valid. Each time period format of the time zone:
HH MM-HH MM, which is accurate to minutes according to the 24-hour clock.
Click Time Rule Setting on the Access Control interface.
1.
Click the grey box to input a time zone to search.
Enter the number of time zone (maximum: 50
zones).
2.
Click the date on which time zone settings is
required. Enter the starting and ending time, and
then press OK.