- 85 -
L5034G4
www.NewLeader.com
(800) 363-1771
305438-J
Calibration
CFR Values
Bin
Value
Main Bin
0�256
Insert Bin
0�144
Yellow Micro Bin
0�038
Red Micro Bin
0�019
Control Valve Settings
Control Valve
Control Variable
Main
Insert
Micro 1
Micro 2
Control Valve Type
Servo
Servo
Servo
Servo
Valve Response 1
40
40
40
40
Valve Response 2
8
8
8
8
Response Threshold
4�0
4�0
4�0
4�0
Allowable Error
1
1
1
1
Sensor Settings
Encoder pulses
180 or 360 - verify by looking on encoder
Spinner pulses
4
Alarms
Alarm Settings
Alarm Variable
Bin
Main (PSI) Insert (PSI) Micro 1 (PSI) Micro 2 (PSI)
Min Conveyor Speed
5
5
3
3
Max Conveyor Speed
50
60
85
85
Max Conveyor Pressure - Std
Hydraulics
2000
2000
-
-
Max Conveyor Pressure - HP
Hydraulics
3400
2000
Rate Responding Time
5
5
5
5
Rate Responding Threshold
30
30
30
30
Max System Pressure - Spinner
3100
-
-
-
Controller Operations
Summary of Contents for L5034 G4
Page 6: ...Insert Current New Leader Warranty Warranty...
Page 7: ...SAFETY...
Page 26: ...INSTALLATION...
Page 35: ...33 This page is intentionally left blank L5034G4 www NewLeader com 800 363 1771 305438 J Notes...
Page 36: ...34 This page is intentionally left blank www NewLeader com 800 363 1771 305438 J L5034G4 Notes...
Page 37: ...OPERATIONS MAINTENANCE...
Page 50: ...47 L5034G4 www NewLeader com 800 363 1771 305438 J Troubleshooting Hydraulic Schematic...
Page 54: ...CONTROLLER...
Page 91: ...SPREAD PATTERN...
Page 102: ...PARTS...
Page 114: ...108 www NewLeader com 800 363 1771 305438 J L5034G4 Main Bin Body Hydraulics...
Page 115: ...109 L5034G4 www NewLeader com 800 363 1771 305438 J Main Bin Cont Body Hydraulics...