INTRODUCTION
Alarm
Alarm
description
Alarm explanation
Prior-
ity
Activation
Time
Resetting
Time
White
Gearbox oil
temperature <
5 °C
AND hydraulic oil
temperature <
20 °C
AND engine not
running
2 s
Gearbox oil
temperature
≥
5 °C
AND
hydraulic oil
temperature
≥
20 °C
AND
engine running
5 s
Yellow
Gearbox oil
temperature <
5 °C
AND hydraulic oil
temperature <
20 °C
AND engine speed <
900 RPM
2 s
Gearbox oil
temperature
≥
5 °C
AND
hydraulic oil
temperature
≥
20 °C
AND
engine speed ≥
900 RPM
5 s
A3214
Gearbox oil
temperature low
The temperature of
the gearbox oil is too
low. Let the engine
run at LOW IDLE to
warm up the oil
Red
Gearbox oil
temperature <
5 °C
AND hydraulic oil
temperature <
20 °C
AND engine speed >
900 RPM
2 s
Gearbox oil
temperature
≥
5 °C
AND
hydraulic oil
temperature
≥
20 °C
AND
engine speed ≤
900 RPM
5 s
A3215
Additives tank
level low
Add additives.
White
additives system
= enabled AND
in field mode AND
additives level sensor
= installed & valid
AND tank level <
5%
10 s
Additives system
≠ enabled OR
not in field mode
OR (additives
system ≠ manual
AND additive
system ≠
automatic) AND
tank level >
5%
5 s
A3216
Additives flow
not reachable
The pump is at its
limits but the flow
can't be reached
(additive viscosity <>
1).
Change settings AND
/ OR nozzle.
White
Additives system
= enabled AND
in field mode AND
additives system =
automatic AND
offs
theoretical_pwm <
10%
OR
>
100%
(pump
pwm pulse width
modulation)
10 s
Additives system
≠ enabled OR not
in field mode OR
additives system
≠ automatic AND
offs
theoretical_pwm
>
10%
AND <
100%
(pump
pwm pulse width
modulation)
5 s
A3217
Additives
working mode
not functioning
The chosen additives
working mode can't
function. Yield
AND/OR moisture is
not installed OR not
functioning. Additives
system stopped.
White
additives system =
enabled AND
(additives working
mode = wet yield
OR additives working
mode = dry yield)
AND
(yield sensor not
installed
OR yield not valid))
3 s
Additives system
≠ enabled OR not
in field mode OR
automatic mode
setting ≠ yield
AND automatic
mode setting
≠ dry yield OR
(yield sensor
installed AND
yield valid)
3 s
48142788 28/04/2017
43
Summary of Contents for 555912001
Page 9: ...48142788 28 04 2017 Find manuals at https best manuals com...
Page 10: ...INTRODUCTION 48142788 28 04 2017 1 Find manuals at https best manuals com...
Page 30: ...INTRODUCTION ZEIL06CS0135F0A 3 48142788 28 04 2017 21...
Page 61: ...INTRODUCTION 48142788 28 04 2017 52...
Page 81: ...This as a preview PDF file from best manuals com Download full PDF manual at best manuals com...