MAN056     Rev Date 07/24/2006

 

 

TRADEMARK 

 XTENDEX is a trademark of Network Technologies Inc in the U.S. and other countries. 
 

COPYRIGHT 

Copyright © 2002-2006 by Network Technologies Inc.  All rights reserved.  No part of this publication may be reproduced, stored 
in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, 
without the prior written consent of Network Technologies Inc, 1275 Danner Drive, Aurora, Ohio 44202. 

 

CHANGES 

The material in this guide is for information only and is subject to change without notice.  Network Technologies Inc reserves the 
right to make changes in the product design without reservation and without notification to its users. 
 
 
 
 
 
 
 
 
.     
 
 
 
 
 

Note:  Shielded CAT 5,5e, or 6 cable must be used to connect to LOCAL and REMOTE units in order to meet CE emission 
requirements. 

 

 
 

Note: CAT5 connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series products 
should not be run underground, outdoors or between buildings.       

 
 
 
 

                     WARNING: Outdoor or underground runs of CAT5 cable could be dangerous and will void the warranty. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

!

Summary of Contents for XTENDEX ST-C5KVM

Page 1: ...24 2006 ST C5KVM Universal KVM Extender Installation and Operation Manual XTENDEXTM Series NETWORK TECHNOLOGIES INCORPORATED Tel 330 562 7070 Fax 330 562 1999 1275 Danner Dr Aurora OH 44202 www networ...

Page 2: ...rive Aurora Ohio 44202 CHANGES The material in this guide is for information only and is subject to change without notice Network Technologies Inc reserves the right to make changes in the product des...

Page 3: ...Introduction 1 Materials 1 Preparation for Installation 2 Installation 3 The Local Unit 3 The Remote Unit 4 Plug in and Boot Up 4 Video Quality 5 Jumper Settings 5 Technical Specifications 6 Intercon...

Page 4: ...ng needs Compatible with PC and SUN computers Contact our sales department for details Video quality adjustment for varying lengths of cable is automatic providing optimum image quality MATERIALS Mate...

Page 5: ...d polarized and preferably surge protected 120V or 240V electrical outlet depending on the AC adapter being used must be installed close enough to the mounting location of each Unit the Remote and Loc...

Page 6: ...d cable VKTINT 3 MM or SKTINT 3 MM to the KB Mouse port on the back of the Local Unit 4 Connect the end of the KB Mouse cable with the keyboard symbol on it to the keyboard port on the back of the CPU...

Page 7: ...in accordance with the Preparation for Installation instructions on page 2 Connect the CAT5 cable to the CAT5 port on the back of the Remote Unit If an RJ45 wall outlet is being used connect the other...

Page 8: ...k transition If a colored vertical line can be seen at the edge of the white window the adjustment may be needed According to the color of the line and the chart below change the jumper position until...

Page 9: ...or 240V at 50 or 60Hz 5VDC 2A via AC Adapter Size In WxDxH Plastic Case 8x6 2x2 6 Rack Mount 19x10x3 5 INTERCONNECTION CABLE WIRING METHOD The connection cable between the remote and local is termina...

Page 10: ...les are not firmly seated CAT5 cable is too long The CAT5 cable is not properly connected Video compensation is not set properly Check all connections Make sure all cables are fully seated Verify leng...

Page 11: ...e keyboard and mouse Reseat cable connections and reboot CPU Reseat cable connections and reboot CPU Note CAT5 connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series p...