Chapter 5: Error Messages and Troubleshooting
39
Operational
messages
The following table describes the operational error messages that might appear
on the C2100 appliance LCD or on the C1200 console, if the appliance
encounters errors during operation.
Power voltage sensors
Baseboard 1.25V
Baseboard 1.25V
Baseboard 2.5V
Baseboard 2.5V
Baseboard 3.3V
Baseboard 3.3V
Baseboard 3.3VSB
Baseboard 3.3VSB
Baseboard 5.0V
Baseboard 5.0V
Baseboard 12V
Baseboard 12V
Baseboard -12V
Baseboard -12V
Baseboard VBAT
Baseboard VBAT
Baseboard VRM
Baseboard VRM
Power supply sensors
Power Supply 1
Power Supply 1
Power Supply 2
N/A
Sensor type
C2100 sensors
C1200 sensors
Error message
Explanation
Corrective action
Disk n is broken
n
—The RAID group disk number.
The solution depends on whether you
have a hot spare in the system—
C2100 only.
See the
System Administration Guide
for information about how to locate a
disk based on the RAID group disk
number and how to replace a faulty
disk.
Fans stopped; replace
them
One of the fan subassemblies of the
appliance failed.
Replace the failed fan subassembly as
soon as possible.
Power supply degraded
One of the power supply units is
turned off, was removed from the
appliance, or failed.
Verify that both power supplies are
installed and turned on. If you still get
this error, replace the power supplies
one at a time to determine the failed
power supply.
Summary of Contents for C1200 NetCache
Page 10: ...x Preface...